DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

CT25-T データシートの表示(PDF) - LEM Industrial

部品番号
コンポーネント説明
メーカー
CT25-T
LEM
LEM Industrial LEM
CT25-T Datasheet PDF : 3 Pages
1 2 3
Current Transducer CT 5 .. 25-T
For very accurate measurements of currents : DC, AC, pulsed...,
with a galvanic isolation between the primary circuit (high power)
and the secondary circuit (electronic circuit).
IPN = 5 .. 25 A
0632
Electrical data
Primary nominal
current
IPN (A r.m.s.)
Primary current,
measuring range
IP (A)
5
7.5
10
15
25
37.5
V
OUT
RL
C
L
tC
V
C
IC
Analog output voltage
Load resistance
Capacitance loading
Output short-circuit duration 1)
Supply voltage (± 5 %)
Current consumption
Conversion
ratio
K N (A/V)
5 A/5 V
10 A/ 5 V
25 A/5 V
Accuracy - Dynamic performance data
X
Overall accuracy @ I
G
PN
- 25°C .. + 70°C
VO
Offset voltage @ I P = 0
TA = 25°C
- 25°C .. + 70°C
f
Frequency bandwidth (- 3 dB) @ 10 % of I
PN
tr
Response time
General data
TA
Ambient operating temperature
T
Ambient storage temperature
S
m
Mass
Standards
Type
CT 5-T
CT 10-T
CT 25-T
5
V
> 500
5
nF
s
± 15
V
30 + VOUT / RL mA
± 0.1
%
Max
± 0.4
mV
± 0.6
mV
DC .. 500
kHz
<1
µs
- 25 .. + 70
°C
- 40 .. + 85
°C
670
g
EN 50178 : 1996
Features
Closed loop (compensated) current
transducer
Insulated plastic case recognized
according to UL 94-V0
Patent pending.
Advanced features
f = 500 kHz
X G = ± 0.1 % (- 25°C .. + 70°C).
Advantages
Excellent accuracy
Very good linearity
Low temperature drift
Optimized response time
Wide frequency bandwidth
No insertion losses
High immunity to external
interference
Current overload capability.
Applications
AC variable speed drives and servo
motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies
(UPS)
Switched Mode Power Supplies
(SMPS)
Power supplies for welding
applications.
Note :
1) If the short-circuit has a duration more than 1 s, the primary current of
the supply voltage must be interrupted for a short time to restore the
transducer to proper working order. The internal protection is done by
PTC resistors.
Application domain
Industrial.
060927/0
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
Page 1/3
www.lem.com

Share Link: 