CXA2153S
No. Measurement item Symbol
8 Drive control
GDRV
Measurement contents
Measure the level of the output signal
amplitude Vout when a 0.7Vp-p video
signal is input.
Contrast = FF/DRIVE = 00
Input signal
0.7Vp-p
Min. Typ. Max. Unit
–100 0 120 mVp-p
GOSD1
Measure the OSD level of the output signal
when the OSD pulse is input.
GOSD1: OSD = FF/DRIVE = FF
GOSD2: OSD = 00/DRIVE = FF
4 4.57 5.15 Vp-p
9 OSD gain control
GOSD2
OSD period
RGB output signal
OSD
level
–330 0 360 mVp-p
10 Relative OSD
OSDGAP
VBRT1
Calculate the difference in the data obtained
in No.9 between the channels.
–200
0
200 mV
Measure the black level of the RGB output
signal.
VBRT1: Brightness = 00
VBRT2: Brightness = FF
0.6 0.8 0.95
11 Brightness control
RGB output signal
V
VBRT2
GND
Black level
2.5 2.93 3.28
12 Relative brightness
VBRTGAP
Calculate the difference in the data obtained
in No.11 between the channels.
–200
0
Measure the BLK level of the output signal
when a BLK pulse is input.
200 mV
13 BLK level
VBLK
GND
BLK level
0.13 0.43 0.74 V
– 13 –