DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

DS1854 データシートの表示(PDF) - Maxim Integrated

部品番号
コンポーネント説明
メーカー
DS1854 Datasheet PDF : 22 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
Dual Temperature-Controlled Resistors with
Two Monitors
Pin Descriptions
PIN BALL NAME
FUNCTION
1
B2
SDA 2-Wire Serial Data I/O pin. This pin is for serial data transfer to and from the device.
2
A2
SCL 2-Wire Serial Clock Input. The serial clock input is used to clock data into and out of the device.
3
C3 OUT1 Open-Drain Buffer Output
4
A1
IN1 TTL/CMOS-Compatible Input to Buffer
5
B1 OUT2 Open-Drain Buffer Output
6
C2
IN2 TTL/CMOS-Compatible Input to Buffer
7
C1
WPEN Write Protect Enable. The device is not write protected if WPEN is connected to ground. This pin has
an internal pullup (RWPEN). See Table 6.
8
D1
GND Ground
9
D3
RHIZ Resistor Disable Input. When high, this signal places both resistors in an off-state or high-impedance
mode. When low, the resistors are on. This pin has an internal pullup (RRHIZ).
10
D4 MON1 External Analog Input
11
C4 MON2 External Analog Input
Low-End Resistor 0 Terminal. It is not required that the low-end terminals be connected to a potential
12
D2
L0 less than the high-end terminals of the corresponding resistor. Voltage applied to any of the resistor
terminals cannot exceed the power-supply voltage, VCC, or go below ground.
High-End Resistor 0 Terminal. It is not required that the high-end terminals be connected to a
13
B3
H0 potential greater than the low-end terminals of the corresponding resistor. Voltage applied to any of
the resistor terminals cannot exceed the power-supply voltage, VCC, or go below ground.
14
B4
L1 Low-End Resistor 1 Terminal
15
A4
H1 High-End Resistor 1 Terminal
16
A3
VCC Supply Voltage
Detailed Description
The user can read the registers that monitor the VCC,
MON1, MON2, and temperature analog signals. After
each signal conversion, a corresponding bit is set that
can be monitored to verify that a conversion has
occurred. The signals also have alarm flags that notify
the user when the signals go above or below the user-
defined value. Interrupts can also be set for each signal.
The position values of each resistor can be indepen-
dently programmed. The user can assign a unique
value to each resistor for every 2°C increment over the
-40°C to +102°C range. Both resistors can also be put
in a high-impedance mode using the RHIZ pin.
Two buffers are provided to convert logic-level inputs
into open-drain outputs. Typically these buffers are
used to implement transmit (Tx) fault and loss-of-signal
(LOS) alarms. Additionally, OUT1 can be asserted in
the event that one or more of the monitored values go
beyond user-defined limits.