pASIC 3 FPGA Family Data Sheet Rev. D
DC Characteristics
The DC specifications are provided in Table 8 through Table 10.
Table 8: Absolute Maximum Ratings
Parameter
VCC Voltage
VCCIO Voltage
Input Voltage
Latch-up Immunity
Value
-0.5 V to 4.6 V
-0.5 V to 7.0 V
-0.5 V to VCCIO +0.5 V
±200 mA
Parameter
DC Input Current
ESD Pad Protection
Storage Temperature
Lead Temperature
Value
±20 mA
±2000 V
-65°C to +150°C
300°C
Table 9: Operating Range
Symbol
Parameter
Military
Industrial
Commercial
Unit
Min. Max. Min. Max. Min.
Max.
VCC
VCCIO
TA
Supply Voltage
I/O Input Tolerance Voltage
Ambient Temperature
3.0 3.6 3.0 3.6
3.0
3.6
V
3.0 5.5 3.0 5.5
3.0
5.25
V
-55
-
-40
85
0
70
°C
TC
Case Temperature
-
125
-
-
-
-
°C
-0 Speed Grade
-
-
0.43 1.90 0.46
1.85
n/a
-1 Speed Grade 0.42 1.64 0.43 1.54 0.46
1.50
n/a
K
Delay Factor -2 Speed Grade 0.42 1.37 0.43 1.28 0.46
1.25
n/a
-3 Speed Grade
0.43 0.90 0.46
0.88
n/a
-4 Speed Grade
0.43 0.82 0.46
0.80
n/a
Table 10: DC Characteristics
Symbol
VIH
VIL
Parameter
Input HIGH Voltage
Input LOW Voltage
VOH Output HIGH Voltage
VOL
II
IOZ
CI
IOS
ICC
ICCIO
Output LOW Voltage
I or I/O Input Leakage Current
3-State Output Leakage Current
Input Capacitanceb
Output Short Circuit Currentc
D.C. Supply Currentd
D.C. Supply Current on VCCIO
Conditions
IOH = -12 mA
IOH = -500 µA
IOL = 16 mAa
IOL = 1.5 mA
VI = VCCIO or GND
VI = VCCIO or GND
VO = GND
VO = VCC
VI, VIO = VCCIO or GND
Min.
0.5 VCC
-0.5
2.4
0.9 VCC
-10
-10
-15
40
0.50 (typ)
0
Max.
VCCIO+0.5
0.3 VCC
VCC
VCC
0.45
0.1 VCC
10
10
10
-180
210
2
100
Units
V
V
V
V
V
V
µA
µA
pF
mA
mA
mA
µA
a. Applies only to -1/-2/-3/-4 commercial grade devices. These speed grades are also PCI-compliant. All other devices have 8 mA IOL
specifications.
b. Capacitance is sample tested only. Clock pins are 12 pF maximum.
c. Only one output at a time. Duration should not exceed 30 seconds.
d. For -1/-2/-3/-4 commercial grade devices only. Maximum ICC is 3 mA for -0 commercial grade and all industrial grade devices and
5 mA for all military grade devices. For AC conditions, contact QuickLogic customer applications group (see “Contact Information”