Specifications
Coil Ratings
Rated Voltage
(VDC)
Rated current Coil resistance
(mA)
(Ω)
Must operate
voltage
5
72
69.4
75% max.
9
40
225
12
30
400
24
15
1600
48
10
4800
Must release
voltage
10% min.
Rated power
consumption
(W)
Approx. 0.36
Approx. 0.48
Max voltage
130% of rated voltage
at 85°C
170% of rated voltage
at 23°C
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with tolerances of ±10%.
2. Please avoid ultrasonic cleaning this relay.
Contact Ratings
Rated load
(resistive)
SPST-NO
SPDT
High-capacity
Rated carry current
Max. switching voltage
Max. switching current
Max. switching capacity
Min. permissible load
Contact Material
10 A @ 250 VAC (NO)
10 A @ 24 VDC (NO)
5 A @ 125 VAC (NO/NC) 5 A @ 24 VDC (NO/NC)
5 A @ 250 VAC (NO/NC) 5 A @ 24 VDC (NO/NC)
10 A (SPST-NO) 10 A (High-capacity)
5 A (SPDT)
250 VAC
24 VDC
10 A
SPST-NO
5A
SPDT, High-capacity
2500 VA, 240 W (NO)
625 VA, 120 W (NC) 1250 VA, 120 W (NO/NC High-capacity)
100 mA at DC5V (P level: λ 60 = 0.1 x 10-6 / ops)
AgSnO2
Note: SPDT type can switch up to 10 A @ 250 VAC/24 VDC Resistive Load on NO contact if there is no load on the NC contact.
Characteristics
Contact resistance
Operate time
Release time
Max. operating frequency
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
Life expectancy
Ambient temperature
Ambient humidity
Weight
100 mΩ max.
10 ms max.
5 ms max.
Mechanical: 18,000 operations/hr
Electrical: 1,800 operations/hr (under rated load)
1,000 MΩ min. (at 500 VDC)
2,000 VAC, 50/60 Hz for 1 minute between coil and contacts
750 VAC, 50/60 Hz for 1 minute between contacts of same polarity
Destruction: 10 to 55 Hz, 1.5-mm double amplitude
Malfunction: 10 to 55 Hz, 1.5-mm double amplitude
Destruction: 1,000 m/s2 (approx. 100G)
Malfunction: 100 m/s2 (approx. 10G)
Mechanical: 10,000,000 operations min. (at 18,000 operations/hr under no load)
Electrical: 100,000 operations average. (at 1,800 operations/hr under rated load)
Operating:- 40°C to 85°C (with no icing or condensation)
Storage: -40°C to 85°C (with no icing or condensation)
Operating: 35% to 85%
Storage: 35% to 85%
Approx. 7.5g
Note: 1. Data shown are of initial value.