GM317L
3-TERMINAL 100mA
ADJUSTABLE REGULATOR
Electrical Characteristics (Unless otherwise noted, VI - VO = 5V and IO= 40mA. TJ = 0°C to
125°C, unless otherwise noted)
Parameter
Symbol
Test Condition
Min Typ Max Unit
Line Regulation (note 2)
Load regulation
Adjustment Pin Current
Adjustment Pin Current
Change
Reference Voltage
Minimum Load Current
Maximum Output Current
Ripple Rejection Ratio
Long Term Stability
(Note 3)
ΔVOI
ΔVOL
IADJ
ΔIADJ
IO(MAX)
3V ≤ VIN – VOUT ≤ 40V, TA = 25°C
3V ≤ VIN – VOUT ≤ 40V,
10mA ≤ IOUT ≤ 100mA, VO ≤ 5V
TA = 25°C
VO > 5V
10mA ≤ IOUT ≤ 100mA
VO ≤ 5V
VO > 5V
3V ≤ VIN – VOUT ≤ 40V
10mA ≤ IOUT ≤ 100mA
3V ≤ VIN – VOUT ≤ 40V,
10mA ≤ IOUT ≤ 100mA,
VIN – VOUT ≤ 40V
VIN – VOUT ≤ 40V, TA = 25°C
VIN – VOUT ≤ 15V
VOUT = 10V, f = 120Hz
VOUT = 10V, f = 120Hz, 10μF
capacitor between ADJ and GND
TA = 125 OC, 1000hr
0.01 0.04
%/V
0.02 0.07
5
25
mV
0.1
0.5 %/ VO
20
70
mV
0.3
1.5 %/ VO
50
100
µA
0.2
5.0
µA
1.2 1.25 1.3
V
3.5
10
mA
25
50
mA
100 200
65
dB
66
80
0.3
%
Output Noise Voltage
10Hz ≤ f ≤ 10KHz, TA = 25°C
0.003
%
Note 1: All characteristics are measured with a 0.1µF capacitor across the input and a 1µF capacitor across the output.
Note 2: Input regulation is expressed here as the percentage change in output voltage per 1V change at the input.
Note 3: Since long-term drift cannot be measured on the individual devices prior to shipment, this specification is not intended to
be a guarantee or warranty. It is an engineering estimate of the average drift to be expected from lot to lot.
4