7
Package Characteristics
All typical values at TA = 25˚C.
Parameter
Sym. Min. Typ. Max. Units
Test Conditions
Fig. Note
Side 1 – Side 2
VISO 2500
Momentary Withstand
Voltage*
Vrms RH < 50%, t = 1 min.,
TA = 25°C
9,10
Side 1 – Side 2
R1–2
1012 RH 45%, t = 5S,
9
Resistance
VI–O = 500 Vdc
Side 1 – Side 2
C1–2
0.25
pF f = 1 MHz
9
Capacitance
-
* The Input–Output Momentary Withstand Voltage is a dielectric voltage rating that should not be interpreted as an input-output
continuous voltage rating. For the continuous voltage rating refer to the VDE 0884 Insulation Characteristics Table (if applicable),
your equipment level safety specification or HP Application Note 1074 entitled “Optocoupler Input–Output Endurance Voltage,”
publication number 5963-2203E.
Notes:
1. Derate linearly above 90˚C free-air temperature at a rate of 3.0 mW/˚C.
2. In the VCC common configuration, Input LED current is a function of the VCC supply voltage. See application information section
to set the proper drive currents.
3. Each channel.
4. DC CURRENT TRANSFER RATIO is defined as the ratio of output collector current, IO, to the forward LED input current IF,
times 100%.
5. The 1.9 kload represents 1 TTL load of 1.6 mA and 5.6 kpull-up resistor.
6. Use of a 0.1 µF bypass capacitor connected between pins 1 and 3, & 5 and 7 adjacent to the device is recommended.
7. Common mode transient immunity in a Logic High level is the maximum tolerable (positive) dVCM /dt of the common mode pulse,
VCM, to assure that the output will remain in a Logic High state (i.e., VO > 2.0 V).
Common mode transient immunity in a Logic Low level is the maximum tolerable (negative) dVCM /dt of the common mode pulse,
VCM, to assure that the output will remain in a Logic Low state (i.e., VO < 0.8 V).
8. The frequency at which the ac output voltage of 3 dB below the low frequency asymptote.
9. Device considered a two-terminal device. Pins 1, 2, 3, and 4 shorted together and Pins 5, 6, 7, and 8 shorted together.
10. In accordance with UL 1577, each optocoupler is proof tested by applying an insulation test voltage 3000 Vrms for 1 second
(leakage detection current limit, II–O < 5 µA).

Share Link: 