DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

HV508LG(2001) データシートの表示(PDF) - Supertex Inc

部品番号
コンポーネント説明
メーカー
HV508LG
(Rev.:2001)
Supertex
Supertex Inc Supertex
HV508LG Datasheet PDF : 3 Pages
1 2 3
HV508
Electrical Characteristics
DC Electrical Characteristics (over operating supply voltages unless otherwise specified, TA = -5°C to +60°C)
Symbol
Parameter
Min Typ Max Unit
Conditions
IHVQ
HVIN quiescent current
ILVQ
LVIN quiescent current
IDDQ
VDD quiescent current
IHV
HVIN operating current
10
µA
10
µA
10
µA
2.8
mA POL = 100Hz, HVEN = high,
TA = 25°C, Load = 1Min parallel
with 0.1µF between HVOUT1 and
HVOUT2
ILV
LVIN operating current
380
µA POL = 100Hz, HVEN = low,
TA = 25°C, Load = 1Min parallel
with 0.1µF between HVOUT1 and
HVOUT2
IIL
Logic input current low
-5
µA
IIH
Logic input current high
5.0
µA
CLOAD
Output capacitive load*
0
0.25
µF
CLOAD in parallel with a 1Mresistor
*The device can operate continuously without any damage within this range. AC limits are not implemented.
AC Electrical Characteristics (HVIN = 45V, LVIN = 6V, VDD = 5V, TA = -5°C to +60°C)
Symbol
Parameter
Min Typ Max Unit
Conditions
fPOL
tHV(ON)
tHV(OFF)
POL input frequency
0
Turn-on time when high voltage is enable
Turn-off time when high voltage is enabled
100
Hz
16
µs Load = 1Min parallel with 0.1µF
between HVOUT1 and HVOUT2.
16
µs
HVEN = High. Outputs rise to HVIN.
See Fig. 1.
tLV(ON)
tLV(OFF)
Turn-on time when high voltage is disabled
Turn-off time when high voltage is disabled
40
µs Load = 1Min parallel with 0.1µF
between HVOUT1 and HVOUT2.
6.0
µs
HVEN = Low. Outputs rise to LVIN.
See Fig. 1.
tEN(ON)
Turn-on time from HVEN to HVOUT
25
µs Load = 1Min parallel with 0.1µF
between HVOUT1 and HVOUT2.
See Fig. 2.
Recommended Operating Conditions
Symbol
VDD
LVIN
HVIN
VIL
VIH
TA
Parameter
Logic supply voltage
Low output supply voltage
High output supply voltage
Logic input voltage low
Logic input voltage high
Ambient Temperature
Notes:
Power-up sequence should be the following:
1. Connect GND, VDD, logic inputs, HVIN, and LVIN.
Power-down sequence should be the reverse of the above.
Min Typ Max
5.0
10.0
3.0
6.0
5.0
45
0
0.7VDD
-5.0
0.3VDD
VDD
+60
Unit
V
V
V
V
V
°C
2