IDT54/74FCT646T/AT/CT
FAST CMOS OCTAL TRANSCEIVER/REGISTER (3-STATE)
MILITARY AND INDUSTRIAL TEMPERATURE RANGES
FUNCTION TABLE(1)
Inputs
Data I/O(2)
G
DIR
CPAB CPBA SAB SBA
A1 - A8
B1 - B8
Operation or Function
H
X
H or L H or L
X
X
Input
Input
Isolation
H
X
X
X
Store A and B Data
L
L
X
X
X
L
Output
Input
Real-Time B Data to A Bus
L
L
X
H or L
X
H
Stored B Data to A Bus
L
H
X
X
L
X
Input
Output
Real-Time A Data to B Bus
L
H
H or L
X
H
X
Stored A Data to B Bus
NOTES:
1. H = HIGH
L = LOW
X = Don't Care
= LOW-to-HIGH transition.
Select control = L: clocks can occur simultaneously.
Select control = H: clocks must be staggered in order to load both registers.
2. The data output functions may be enabled or disabled by various signals at the GAB or GBA inputs. Data input functions are always enabled, i.e. data at the bus pins will be
stored on every LOW-to-HIGH transition on the clock inputs.
3. A in B Register.
4. B in A Register.
DC ELECTRICAL CHARACTERISTICS OVER OPERATING RANGE
Following Conditions Apply Unless Otherwise Specified:
Industrial: TA = –40°C to +85°C, VCC = 5.0V ±5%; Military: TA = –55°C to +125°C, VCC = 5.0V ±10%
Symbol
Parameter
Test Conditions(1)
Min. Typ.(2)
Max.
Unit
VIH
Input HIGH Level
Guaranteed Logic HIGH Level
VIL
Input LOW Level
Guaranteed Logic LOW Level
IIH
Input HIGH Current(4)
VCC = Max.
VI = 2.7V
IIL
Input LOW Current(4)
VCC = Max.
VI = 0.5V
IOZH
High Impedance Output Current VCC = Max
VO = 2.7V
IOZL
(3-State output pins)(4)
VO = 0.5V
II
Input HIGH Current(4)
VCC = Max., VI = VCC (Max.)
VIK
Clamp Diode Voltage
VCC = Min, IIN = -18mA
VH
Input Hysteresis
ICC
Quiescent Power Supply Current VCC = Max., VIN = GND or VCC
2
V
0.8
V
±1
µA
±1
µA
±1
µA
±1
±1
µA
–0.7
–1.2
V
200
mV
0.01
1
µA
OUTPUT DRIVE CHARACTERISTICS
Symbol
Parameter
Test Conditions(1)
VOH
Output HIGH Voltage
VCC = Min
IOH = –6mA MIL
VIN = VIH or VIL
IOH = –8mA IND
IOH = –12mA MIL
IOH = –15mA IND
VOL
Output LOW Voltage
VCC = Min
IOL = 48mA MIL
VIN = VIH or VIL
IOL = 64mA IND
IOS
Short Circuit Current
VCC = Max., VO = GND(3)
IOFF
Input/Output Power Off Leakage(5) VCC = 0V, VIN or VO 4.5V
Min. Typ.(2)
Max.
Unit
2.4
3.3
V
2
3
0.3
0.55
V
–60
–120
–225
mA
±1
µA
NOTES:
1. For conditions shown as Min. or Max., use appropriate value specified under Electrical Characteristics for the applicable device type.
2. Typical values are at VCC = 5.0V, +25°C ambient.
3. Not more than one output should be tested at one time. Duration of the test should not exceed one second.
4. The test limit for this parameter is ±5µA at TA = –55°C.
5. This parameter is guaranteed but not tested.
3