Specifications ispLSI 2064V
Absolute Maximum Ratings 1
Supply Voltage Vcc ................................................... -0.5 to +5.6V
Input Voltage Applied ..................................... -0.5 to +5.6V
Off-State Output Voltage Applied .................. -0.5 to +5.6V
Storage Temperature ..................................... -65 to 150°C
S Case Temp. with Power Applied .................... -55 to 125°C
N Max. Junction Temp. (TJ) with Power Applied ............ 150°C
IG 1. Stresses above those listed under the “Absolute Maximum Ratings” may cause permanent damage to the device. Functional
S operation of the device at these or at any other conditions above those indicated in the operational sections of this specification
DE is not implied (while programming, follow the programming specifications).
DC Recommended Operating Condition
W SYMBOL
E VCC
N VIL
FOR VIH
Supply Voltage
Input Low Voltage
Input High Voltage
PARAMETER
Commercial TA = 0°C to + 70°C
Industrial
TA = -40°C to + 85°C
MIN.
3.0
3.0
VSS – 0.5
2.0
MAX. UNITS
3.6
V
3.6
V
0.8
V
5.25
V
Table 2-0005/2064V
Capacitance (TA=25°C, f=1.0 MHz)
VE SYMBOL
4 C1
6 C2
0 C3
PARAMETER
Dedicated Input Capacitance
I/O Capacitance
Clock and Global Output Enable Capacitance
SI 2 Data Retention Specifications
ispL Data Retention
PARAMETER
MINIMUM
20
TYPICAL
10
10
13
UNITS
pf
pf
pf
MAXIMUM
–
TEST CONDITIONS
VCC = 3.3V, VIN = 2.0V
VCC = 3.3V, VI/O = 2.0V
VCC = 3.3V, VY = 2.0V
Table 2-0006/2064V
UNITS
Years
USE ispLSI Erase/Reprogram Cycles
10000
–
Cycles
Table 2-0008/2064V
3