DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

L9217G データシートの表示(PDF) - Agere -> LSI Corporation

部品番号
コンポーネント説明
メーカー
L9217G Datasheet PDF : 30 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
L9217A/G Low-Cost Line Interface
with Reverse Battery and PPM
Data Sheet
November 2001
Functional Description
Table 2. Input State Coding
B0 B1 B2
State/Definition
1 1 1 Powerup, Forward Battery, Normal Overhead. Normal talk and battery feed state. Pin PT is
positive with respect to PR. On-hook transmission is enabled. PPM is not active. Overhead is un-
affected by resistor OVH and is adequate for 3.14 dBm overload into 900 .
1 0 1 Powerup, Reverse Battery, Normal Overhead. Normal talk and battery feed state. Pin PT is
negative with respect to PR. On-hook transmission is enabled. PPM is not active. Overhead is un-
affected by resistor OVH and is adequate for 3.14 dBm overload into 900 .
1 1 0 Powerup, Forward Battery, High Overhead. Normal talk and battery feed state. Pin PT is posi-
tive with respect to PR. On-hook transmission is enabled. PPM is not active. Overhead is in-
creased via resistor OVH.
1 0 0 Powerup, Reverse Battery, High Overhead. Normal talk and battery feed state. Pin PT is neg-
ative with respect to PR. On-hook transmission is enabled. PPM is not active. Overhead is in-
creased via resistor OVH.
0 1 1 Low-Power Scan. Except for off-hook detection, all circuits are shut down to conserve power. Pin
PT is positive with respect to pin PR. On-hook transmission is disabled.
0 0 1 Disconnect. The tip and ring amplifiers are turned off, and the SLIC goes to a high-impedance
state (>100 k). Supervision outputs read on hook. Device will power up in this state.
0 0 0 Powerup, Reverse Battery, High Overhead with PPM. Normal talk and battery feed state. Pin
PT is negative with respect to PR. On-hook transmission is enabled. PPM is active. Overhead is
increased via resistor OVH.
0 1 0 Powerup, Forward Battery, High Overhead with PPM. Normal talk and battery feed state. Pin
PT is positive with respect to PR. On-hook transmission is enabled. PPM is active. Overhead is
increased via resistor OVH.
Table 3. Supervision Coding
0 = off-hook or ring trip.
1 = on-hook and no ring trip.
NSTAT
6
Agere Systems Inc.

Share Link: 

datasheetq.com  [ Privacy Policy ]Request Datasheet ] [ Contact Us ]