DRAIN TO SOURCE ON-STATE RESISTANCE
vs. DRAIN CURRENT
70
VGS = 4.0 V
60
50
40
30
TA = 75 ˚C
20
25 ˚C
10
–25 ˚C
0
1
10
100
1 000
ID - Drain Current - mA
CAPACITANCE vs.
DRAIN TO SOURCE VOLTAGE
10
5
Ciss
Coss
2
1
0.5
0.2
VGS = 0
0.1 f = 1 MHz
12
5 10 20
Crss
50 100
VDS - Drain to Source Voltage - V
SOURCE TO DRAIN DIODE
FORWARD VOLTAGE
1
0.1
0.01
0.001
0.4
0.8
1.2
1.6
2
VSD - Source to Drain Voltage - V
2SK2158
DRAIN TO SOURCE ON-STATE RESISTANCE
vs. GATE TO SOURCE VOLTAGE
50
40
ID = 10 mA
30
ID = 100 mA
20
10
0
2
4
6
VGS - Gate to Source Voltage - V
SWITCHING CHARACTERISTICS
100
tr
50
20
tf
td(off)
10
td(on)
5
2
1
10 20
VDD = 3 V
VGS(on) = 3 V
RG = 10 Ω
50 100 200 500 1 000
ID - Drain Current - mA
4