LT1461
ELECTRICAL CHARACTERISTICS The q denotes specifications which apply over the specified temperature
range, otherwise specifications are at TA = 25°C. VIN – VOUT = 0.5V, Pin 3 = 2.4V, CL = 2µF, unless otherwise specified.
PARAMETER
CONDITIONS
MIN TYP
Output Voltage (Note 4)
LT1461ACS8/LT1461AIS8
LT1461BCS8/LT1461BIS8
LT1461CCS8/LT1461CIS8
LT1461DHS8
– 0.04
– 0.06
– 0.08
– 0.15
Output Voltage Temperature Coefficient (Note 5)
LT1461ACS8/LT1461AIS8
q
1
LT1461BCS8/LT1461BIS8
q
3
LT1461CCS8/LT1461CIS8
q
5
LT1461DHS8
q
7
Line Regulation
(VOUT + 0.5V) VIN 20V
2
q
LT1461DHS8
q
15
Load Regulation Sourcing (Note 6)
VIN = VOUT + 2.5V
0 IOUT 50mA
12
q
Dropout Voltage
Output Current
Shutdown Pin
LT1461DHS8, 0 IOUT 10mA
q
VIN – VOUT, VOUT Error = 0.1%
IOUT = 0mA
0.06
IOUT = 1mA
q
0.13
IOUT = 10mA
q
0.20
IOUT = 50mA, I and C Grades Only q
1.50
Short VOUT to GND
100
Logic High Input Voltage
q 2.4
Logic High Input Current, Pin 3 = 2.4V q
2
Logic Low Input Voltage
q
Logic Low Input Current, Pin 3 = 0.8V q
0.5
Supply Current
No Load
35
q
Shutdown Current
RL = 1k
25
q
Output Voltage Noise (Note 7)
0.1Hz f 10Hz
8
10Hz f 1kHz
9.6
Long-Term Drift of Output Voltage, SO-8 Package (Note 8) See Applications Information
60
Thermal Hysteresis (Note 9)
T = 0°C to 70°C
40
T = – 40°C to 85°C
75
T = – 40°C to 125°C
120
MAX
UNITS
0.04
%
0.06
%
0.08
%
0.15
%
3
ppm/°C
7
ppm/°C
12
ppm/°C
20
ppm/°C
8
ppm/V
12
ppm/V
50
ppm/V
30
ppm/mA
40
ppm/mA
50
ppm/mA
V
0.3
V
0.4
V
2.0
V
mA
V
15
µA
0.8
V
4
µA
50
µA
70
µA
35
µA
55
µA
ppmP-P
ppmRMS
ppm/kHr
ppm
ppm
ppm
Note 1: Absolute Maximum Ratings are those values beyond which the life
of a device may be impaired.
Note 2: The LT1461 is guaranteed functional over the operating
temperature range of – 40°C to 125°C.
Note 3: If the part is stored outside of the specified temperature range, or
the junction temperature exceeds the specified temperature range, the
output may shift due to hysteresis.
Note 4: ESD (Electrostatic Discharge) sensitive device. Extensive use of
ESD protection devices are used internal to the LT1461, however, high
electrostatic discharge can damage or degrade the device. Use proper ESD
handling precautions.
Note 5: Temperature coefficient is calculated from the minimum and
maximum output voltage measured at TMIN, Room and TMAX as follows:
TC = (VOMAX – VOMIN)/(TMAX – TMIN)
Incremental slope is also measured at 25°C.
Note 6: Load regulation is measured on a pulse basis from no load to the
specified load current. Output changes due to die temperature change
must be taken into account separately.
Note 7: Peak-to-peak noise is measured with a single pole highpass filter
at 0.1Hz and a 2-pole lowpass filter at 10Hz. The unit is enclosed in a still-
air environment to eliminate thermocouple effects on the leads. The test
time is 10 seconds. RMS noise is measured with a single pole highpass
filter at 10Hz and a 2-pole lowpass filter at 1kHz. The resulting output is
full-wave rectified and then integrated for a fixed period, making the final
reading an average as opposed to RMS. A correction factor of 1.1 is used
to convert from average to RMS and a second correction of 0.88 is used to
correct for the nonideal bandpass of the filters.