First Prev 11 12 13 14 15 16 17 18 19 20
U
OPERATIO
Transitioning from linear regulator mode to VLDO mode,
accomplished by bringing ENBUCK from a logic low to a
logic high while ENVLDO is a logic high, is designed to be
as seamless and transient free as possible. The precise
transient response of LVOUT due to this transition is a
function of COUT and the load current. Waveforms given
in the Typical Performance Characteristics section show
typical transient responses using the minimum COUT of
2.2µF and load currents of 1mA and 30mA respectively.
Generally, the amplitude of any transients present will
decrease as COUT is increased. To ensure reliable operation
and adherence to the load regulation limits presented in
the Electrical Characterstics table, the load current must
not exceed the linear regulator IOUT limit of 30mA within
20ms after ENBUCK has transitioned to a logic high. The
300mA IOUT limit of VLDO applies thereafter. Further,
for configurations that do not use the LTC3541-2’s buck
regulator to provide the VLDO input voltage (LVIN), the user
must ensure a stable LVIN voltage is present no less than
1ms prior to ENBUCK transitioning to a logic high.
LTC3541-2
In a similar manner, transitioning from VLDO mode to
linear regulator mode, accomplished by bringing ENBUCK
from a high low to a logic low while ENVLDO is a logic
high, is designed to be as seamless and transient free as
possible. Again, the precise transient response of LVOUT
due to this transition is a function of COUT and the load
current. Waveforms given in the Typical Performance
Characteristics section show typical transient responses
using the minimum COUT of 2.2µF and load currents of
1mA and 30mA respectively. Generally, the amplitude of
any transients present will decrease as COUT is increased.
To ensure reliable operation and adherence to the load
regulation limits presented in the Electrical Characterstics
table, the load current must not exceed the linear regulator
IOUT limit of 30mA 1ms prior to ENBUCK transitioning to
a logic low and thereafer. Further, for configurations that
do not use the LTC3541-2’s buck regulator to provide the
VLDO input voltage (LVIN), the user must continue to ensure
a stable LVIN voltage no less than 1ms after ENBUCK has
transitioned to a logic low.