DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

CAT24C01BJA データシートの表示(PDF) - Catalyst Semiconductor => Onsemi

部品番号
コンポーネント説明
メーカー
CAT24C01BJA
Catalyst
Catalyst Semiconductor => Onsemi Catalyst
CAT24C01BJA Datasheet PDF : 8 Pages
1 2 3 4 5 6 7 8
CAT24C01B
Acknowledge Polling
The disabling of the inputs can be used to take advan-
tage of the typical write cycle time. Once the stop
condition is issued to indicate the end of the host’s write
operation, the CAT24C01B initiates the internal write
cycle. ACK polling can be initiated immediately. This
involves issuing the start condition followed by the byte
address for a write operation. If the CAT24C01B is still
busy with the write operation, no ACK will be returned.
If the CAT24C01B has completed the write operation, an
ACK will be returned and the host can then proceed with
the next read or write operation.
READ OPERATIONS
The READ operation for the CAT24C01B is initiated in
the same manner as the write operation with the one
exception that the R/W bit is set to a one. Two different
READ operations are possible: Byte READ and Se-
quential READ.
It should be noted that the ninth clock cycle of the read
operation is not a "don't care." To terminate a read
operation, the master must either issure a stop condition
during the ninth cycle or hold SDA HIGH during the ninth
clock cycle and then issue a stop condition.
Byte Read
To initiate a read operation, the master sends a start
condition followed by a seven bit word address and a
read bit. The CAT24C01B responds with an acknowl-
edge and then transmits the eight bits of data. The read
operation is terminated by the master; by not respond-
ing with an acknowledge and by issuing a stop condition.
Refer to Figure 7 for the start word address, read bit,
acknowledge and data transfer sequence.
Sequential Read
The Sequential READ operation can be initiated after
the 24C01B sends the initial 8-bit byte requested, the
Master will respond with an acknowledge which tells the
device it requires more data. The CAT24C01B will
continue to output an 8-bit byte for each acknowledge
sent by the Master. The operation is terminated when
the Master fails to respond with an acknowledge, thus
sending the STOP condition.
The data being transmitted from the CAT24C01B is
output sequentially with data from address N followed by
data from address N+1. The READ operation address
counter increments all of the CAT24C01B address bits
so that the entire memory array can be read during one
operation. If more than bytes are read out, the counter
will “wrap around” and continue to clock out data bytes.
Figure5. Byte Write Timing
S
T
S
BUS ACTIVITY: A WORD
T
R ADDRESS(n)
O
T
P
SDA LINE S
BUS ACTIVITY:
M
S
B
LRA
S/ C
BW K
P
DATA n
A
C
K
Figure 6. Page Write Timing
BUS ACTIVITY:
S
T
A WORD
R ADDRESS(n)
T
SDA LINE S
BUS ACTIVITY:
M
S
B
LRA
S/ C
BW K
DATA n
DATA n+1
A
A
C
C
K
K
S
T
DATA n+3 O
P
P
A
C
K
Doc. No. 1081, Rev. B
6

Share Link: 

datasheetq.com  [ Privacy Policy ]Request Datasheet ] [ Contact Us ]