DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

M62241 データシートの表示(PDF) - MITSUBISHI ELECTRIC

部品番号
コンポーネント説明
メーカー
M62241
Mitsubishi
MITSUBISHI ELECTRIC  Mitsubishi
M62241 Datasheet PDF : 18 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
MITSUBISHI(Standard Linear IC)
M62241FP
SINGLE CHIP BATTERY CHARGER CONTROL IC
7. Detection of battery connection /battery temperature
This block detects the battery connection and the battery temperature by the input voltage dividing
between thermistor inside battery package and resistances outside REFIN pin.
Each referential voltage for detection is set by dividing REFOUT pin voltage by inside resistances.
The dividing circuits are grounded to THS pin connected directly to - terminal of battery
to prevent input voltage of TH pin from changing by the current of external circuit.
<1> Battery connection detection
The battery connection is recognized in case the resistance of the thermistor connected to
TH pin is less than the following:
Thermistor resistance(Rth): less than approximately 100k
Detecting timing is as follows:
60msec * 2 times =120msec(Foc=3.41KHz)
<2> Battery temperature detection
This block controls to switch charging after detecting the battery temperature by the dividing
ratio between resistance pulled up and thermistors.
Detecting timing is as follows:
60msec * 2 times =120msec(Foc=3.41KHz)
For further details,read the 20 clause.
8. Over discharge detection block
In case the voltage majored before starting to charge is less than the detection voltage,the over
discharge mode is taken over before waiting.It continues to wait until the battery charges from
external circuit and the charge mode is taken over after the voltage becomes more than the detection
voltage.The differential gain output voltage of the battery is majored at this block.
The referential voltage for detecting is set by the dividing ratio between resistors connected to the
REFOUT pin.
The Over Discharge detection voltage (V Blow) is 4.0V.
This detection is disregarded during charging.
The detection timing is as follows:
300msec *4 times = 1.2sec. (foc=3.41kHz)
9.Over Voltage detection block
NG mode is taken over ,in case the voltage majored before starting to charge is more than the
following voltage.The referential voltage for detecting is REFOUT output voltage.
The over detection voltage(Vbhigh) is VREFOUT.
This detection is disregarded during charging.
The detection timing is as follows:
300msec *4 times = 1.2sec. (foc=3.41kHz)
10 The charge completion detection block
The charge completion mode is taken over in case the charge current in charge mode is less than the
detection current.
This detection depends on the gained current output.
The referential voltage for detection is set by the dividing ratio between resistors connected to ADJ3
pin.This detection is discharged except during charging.
The detection timings is as follows:
600msec *8 times = 4.8sec. (foc=3.41kHz)