MITSUBISHI(Standard Linear ICs)
M62295GP
PC BACK- LIGHT CONTROL IC
• Protection function (timer-latch) (Cscp1, Cscp2, Iscp)
Application for timer-latch by detecting tube current
and feecback voltage is available by using Iscp,
Cscp1, Cscp2 terminal.
Two kinds of setting for timer-latch time is available
by the setting of Cscp1, Cscp2. Each timer-latch
time is set by the formula below.
Cscp1 :
Terminal for capacitance for timer-latch set (few sec.)
Timer-L (Cscp1) = Cscp1 *
2.5
1.3 * 10 -6
Cscp2 :
Terminal for capacitance for timer-latch set (few msec.)
Timer-L (Cscp2) = Cscp2 *
1.25
1.3 * 10 -6
Detection of tube current
Detection of tube current is made by Iscp terminal.
Detection voltage for Iscp terminal is set 1.25V.
After power is on, when Iscp voltage does not rise
up to 1.25V by timer-L(Cscp1) time, or when Iscp
voltage becomes 1.25V or less after start-up,
abnormality is detected to move on to the protection
operation mode in Fig.1.
If Iscp voltage is less than 1.25V, light control is
not made(100%).
Cscp1
Cscp1
Cscp2
Cscp2
Fig.7 Connections of Cscp1, Cscp2
BL tube current detection
Iscp
Detection of feedback voltage
Detection of feedback voltage is made by FB
terminal.
When FB terminal voltage goes down to FB low
detection voltage (0.25V) or less, or when it rise up
to FB terminal high detection voltage or more,
abnormality is detected to move on to the protection
operation mode in Fig.1.
Fig.8 Connections of Iscp terminal
Operation state
Normal start-up
Protection
operation mode
Triggers for protection operation Timer-latch time
Ampout="H" Ampout="L" Io=0
2sec 10msec
Start-up in
Io=Max Operation stop after 10ms
shortcircuited state Io=0 Operation stop instantaneously
Start-up in open state Operation stop after 2sec.
Start-up in black
mode
OFF Operation stop after 2sec.
Normal start-up if turn-on
ON is made within 2sec.
Shortcircuit while Io=Max Operation stop instantaneously
in operation
Io=0 Operation stop instantaneously
Open while in operation Operation stop instantaneously
Table 1. Protection operation mode at a glance
Note 1. Timer-latch time refers to the time under Cscp=1uF, Cscp2=0.1uF.
2. Amp. output is "H" when tube current I0 equals to 0, "L" when it is at
its minimum. Detection voltage is 2.5V("H" side), 0.25V("L" side).