DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

MAP130 データシートの表示(PDF) - Power-One Inc.

部品番号
コンポーネント説明
メーカー
MAP130 Datasheet PDF : 4 Pages
1 2 3 4
MAP130 SERIES
INTERFACE SIGNALS AND INTERNAL PROTECTION
PARAMETER
Overvoltage Protection
Overcurrent Protection
Remote Sense
Power Fail Warning
(Note 1)
Overtemperature Warning
(Note 2)
CONDITIONS/DESCRIPTION
MIN
NOM
MAX
Provided on single output units and only
the main output of multiple output units.
MAP130-1012 17.0
22.0
MAP130-1024 32.0
37.0
MAP130-4004
6.2
7.4
All other models.
5.5
6.8
All models have inherent short circuit protection. Units will automatically restart at the removal of the fault.
Total voltage compensation for main output cable losses.
250
Logic LO (denotes power fail detected).
0.7
Logic HI with internal pull-up to output.
10
Power Fail trip point, maximum load, decreasing line.
86
94
Time before regulation dropout, at full load, due to loss of input power.
5
Warning prior to system shutdown due to excessive internal temperatures.
20
Shifts Power Fail signal to a logic LO state.
NOTES: 1) Power Fail not available on MAP130-1012 and MAP130-1024.
2) MAP130-1012 and MAP130-1024 have overtemperature protection, but do not have the warning feature.
SAFETY, REGULATORY, AND EMI SPECIFICATIONS
PARAMETER
Agency Approvals
Dielectric Withstand Voltage
Electromagnetic
Interference,
ESD Susceptibility
Radiated Susceptibility
EFT/Burst
Input Transient Protection
Insulation Resistance
Leakage Current
CONDITIONS/DESCRIPTION
UL1950.
CSA 22.2 No. 234/950.
EN60950 (TÜV).
Input to Output, 1 second.
FCC CFR title 47 Part 15 Sub-Part B - Conducted
EN55022 / CISPR 22 Conducted
EN55022 / CISPR 22 Radiated (Note 1)
Per EN61000-4-2, level 4
Per EN61000-4-3, level 3
Per EN61000-4-4, level 3 (Note 2)
Per EN61000-4-5 class 3
Input to output
Per EN60950 (264 VAC)
MIN
2600
B
B
B
8
10
±2
Line to Line 1
Line to Ground 2
7
NOM
MAX
Approved
700
NOTES: 1) MAP130-1005 meets Class A, radiated.
2) MAP130-1005, MAP130-4003, and MAP130-4010, meet level 2, ±1kV.
ENVIRONMENTAL SPECIFICATIONS
PARAMETER
Altitude
Operating Temperature
Storage Temperature
Temperature Coefficient
Relative Humidity
Shock
Vibration
CONDITIONS/DESCRIPTION
Operating
Non-Operating
Derate linearly above 50°C by 2.5% per °C
0°C to 70°C (after 15 minute warm-up period)
Non-Condensing
Operating, peak acceleration
Random vibration, 10Hz to 2kHz, 3 axis
MIN
At 100% load: 0
At 50% load:
-40
5
NOM
±0.02
MAX
10K
40K
50
70
85
±0.05
95
20
6
UNITS
VDC
mV
V
k
VAC
mS
mS
UNITS
VDC
Class
kV
V/M
kV
kV
M
µA
UNITS
Feet
°C
°C
°C
%/°C
%RH
GPK
GRMS
OPTIONS
DESCRIPTION
Cover
NOTES
Add ‘C’ suffix to model number or order part number 412-59586 separately.
For convection cooled applications with covers, derate output power as follows:
Derate all multiple output models and MAP130-1005 to 120 watts.
Derate MAP130-1012 and MAP130-1024 to 140 watts.
DIMENSIONS
8.50" x 4.50" x 2.40"
(215.9mm x 114.3mm x 61.0mm)
3

Share Link: 

datasheetq.com  [ Privacy Policy ]Request Datasheet ] [ Contact Us ]