GaAs SPDT Switch
DC - 3.0 GHz
MASW-008075
V1
Electrical Specifications: TA = 25°C, VC = 0 V / 3 V, Z0 = 50 Ω 4
Parameter
Test Conditions
Units Min. Typ. Max.
Insertion Loss5
Isolation
1.0 GHz
2.4 GHz
1.0 GHz
2.4 GHz
dB
0.3
dB
0.4
0.5
dB
23
dB
23
25
VSWR
0.05 - 3.0 GHz
Ratio
1.2:1
IIP2
Two Tone, +5 dBm / Tone, 5 MHz Spacing
2.4 GHz
dBm
80
IIP3
Two Tone, +5 dBm / Tone, 5 MHz Spacing
2.4 GHz
dBm
48
Input P1dB
dBm
28
Trise, Tfall
10% to 90% RF and 90% to 10% RF
nS
35
Ton, Toff
50% control to 90% RF, 50% control to 10% RF
nS
40
Transients
mV
10
Current
VC = 3.0 V
µA
5
10
4. For positive voltage control, external DC blocking capacitors are required on all RF ports.
5. Insertion Loss can be optimized by varying the DC blocking capacitor value, e.g. 1000 pF for 100 MHz – 1.0 GHz, 39 pF for 0.5 - 3.0 GHz.
Truth Table 6,7
Lead-Free SC-70 (SOT-363)
Control
V1
Control
V2
RFC-RF1 RFC-RF2
0
1
On
Off
1
0
Off
On
6. Differential voltage, V (state 1) - V (state 0), must be +2.3 V
minimum and must not exceed 8.5 V.
7. 0 = 0 V ± 0.2 V, 1 = +2.5 V to 5.0 V
Handling Procedures
The following precautions should be observed to
avoid damage:
Static Sensitivity
Gallium Arsenide Integrated Circuits are sensitive
to electrostatic discharge (ESD) and can be
damaged by static electricity. Proper ESD control
techniques should be used when handling these
devices.
Reference Application Note M538 for lead-free solder reflow
recommendations.
Meets JEDEC moisture sensitivity level 1 requirements.
2
M/A-COM Inc. and its affiliates reserve the right to make changes to the
product(s) or information contained herein without notice. M/A-COM makes
no warranty, representation or guarantee regarding the suitability of its
products for any particular purpose, nor does M/A-COM assume any liability
whatsoever arising out of the use or application of any product(s) or
information.
North America Tel: 800.366.2266 / Fax: 978.366.2266
Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300
Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298
Visit www.macom.com for additional data sheets and product information.

Share Link: 

datasheetq.com  [ Privacy Policy ]Request Datasheet ] [ Contact Us ]