GaAs SP3T 2.7 V CDMA-GPS Switch
DC - 2.5 GHz
MASWSS0060
V4
Electrical Specifications: TA = 25°C, Z0 = 50 1
Parameter
Test Conditions
Insertion Loss2
(All Paths)
1.0 GHz
1.5 GHz
2.0 GHz
Isolation
DC - 1.0 GHz
1.0 - 2.0 GHz
2.0 - 2.5 GHz
Return Loss
(All RF ports)
DC - 2.5 GHz
IP3
Two Tone, +22 dBm/tone, 1 MHz Spacing, 820 MHz
Two Tone, +22 dBm/tone, 1 MHz Spacing, 1880 MHz
Cross Modulation
For Cell Band: Two-tone signal input:
Tx1 = +22 dBm @ 820 MHz, Tx2 = +22 dBm @ 821 MHz,
RX interfere = -23 dBm @ 869 MHz
For PCS Band: Two-tone signal input:
Tx1 = +18 dBm @ 1880 MHz, Tx2 = +18 dBm @ 1881 MHz,
RX interfere = -23 dBm @ 1960 MHz
P.1dB
Vc = 0 V/2.7 V, 1 GHz
Trise, Tfall
10% to 90% RF, 90% to 10% RF, 900 MHz
Ton, Toff
50% control to 90% RF, and 50% control to 10% RF, 900 MHz
Transients
In Band
Control Current
Vc = 0 V/2.7 V
Units
dB
dB
dB
dB
dB
dB
dB
dBm
dBm
dBm
dBm
dBm
µS
µS
mV
µA
Min.
23
18
16
Typ.
0.55
0.60
0.70
27
21
20
20
62
61
-101
-102
36
0.06
0.09
70
Max.
0.70
0.75
0.90
30
1. External DC blocking capacitors are required on all RF ports.
2. Insertion Loss can be optimized by varying the DC blocking capacitor value, e.g. 1000 pF for 100 MHz - 500 MHz, 100 pF for 0.5 - 2.5 GHz.
Absolute Maximum Ratings 3,4
Parameter
Absolute Maximum
Input Power
(0.5 - 2.5 GHz, 2.7 V Control)
+36 dBm
Control Voltage
Operating Temperature
Storage Temperature
±8.5 volts
-40°C to +85°C
-65°C to +150°C
3. Exceeding any one or combination of these limits may cause
permanent damage to this device.
4. M/A-COM does not recommend sustained operation near
these survivability limits.
Truth Table 5,6
V1 V2 V3 ANT-RF1 ANT-RF2 ANT-RF3
1
0
0
On
Off
Off
0
1
0
Off
On
Off
0
0
1
Off
Off
On
5. Differential voltage, V (state 1) -V (state 0) must be 2.6 V
minimum and must not exceed 8.5 V.
6. 0 = -5 V to 2.4 V, 1 = -2.4 V to 5 V.
2
M/A-COM Inc. and its affiliates reserve the right to make changes to the
product(s) or information contained herein without notice. M/A-COM makes
no warranty, representation or guarantee regarding the suitability of its
products for any particular purpose, nor does M/A-COM assume any liability
whatsoever arising out of the use or application of any product(s) or
information.
North America Tel: 800.366.2266 / Fax: 978.366.2266
Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300
Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298
Visit www.macom.com for additional data sheets and product information.

Share Link: 

datasheetq.com  [ Privacy Policy ]Request Datasheet ] [ Contact Us ]