DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

MAX2837(2008) データシートの表示(PDF) - Maxim Integrated

部品番号
コンポーネント説明
メーカー
MAX2837
(Rev.:2008)
MaximIC
Maxim Integrated MaximIC
MAX2837 Datasheet PDF : 18 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
2.3GHz to 2.7GHz Wireless
Broadband RF Transceiver
AC ELECTRICAL CHARACTERISTICS—Rx MODE (continued)
MAX2837 evaluation kit: VCC_ = 2.8V, fRF = 2.502GHz, fLO = 2.5GHz; receiver baseband I/Q outputs at 90mVRMS
(-21dBV), fREF = 40MHz, ENABLE = RXENABLE = CS = high, TXENABLE = SCLK = DIN = low, with power matching for the differential RF
pins using the typical applications and registers set to default settings and corresponding test mode, TA = +25°C, unless otherwise noted.
Lowpass filter is set to 10MHz RF channel BW. Unmodulated single-tone RF input signal is used, unless otherwise indicated.) (Note 1)
PARAMETER
CONDITIONS
MIN
Max RF gain (B7:B6 = 00)
In-Band Input P-1dB
Max RF gain - 8dB (B7:B6 = 01)
Max RF gain - 16dB (B7:B6 = 10)
Max RF gain - 32dB (B7:B6 = 11)
Maximum Output Signal Level
Over passband frequency range; at any gain setting;
1dB compression point
Max RF gain (B7:B6 = 00), AGC set for -65dBm
wanted signal
Out-of-Band Input IP3 (Note 2)
Max RF gain - 8dB (B7:B6 = 01), AGC set for -55dBm
wanted signal
Max RF gain - 16dB (B7:B6 = 10), AGC set for -40dBm
wanted signal
I/Q Phase Error
I/Q Gain Imbalance
Rx I/Q Output Load Impedance
(R || C)
Max RF gain - 32dB (B7:B6 = 11), AGC set for -30dBm
wanted signal
50kHz baseband output; 1 variation
50kHz baseband output; 1 variation
Minimum differential resistance
Maximum differential capacitance
I/Q Output DC Droop
After switching RXHP to 0; average over 1μs after any
gain change, or 2μs after receive enabled with 100Hz
interval AC-coupling, 1 variation
I/Q Static DC Offset
No RF input signal; measure at 3μs after receive
enable; RXHP = 1 for 0 to 2μs and set to 0 after 2μs,
1 variation
Loopback Gain
(for Receiver I/Q Calibration)
Transmitter I/Q input to receiver I/Q output; transmitter
B6:B1 = 000011, receiver B5:B1 = 10100 programmed -4.5
through SPI
RECEIVER BASEBAND FILTERS
At 15MHz
Baseband Filter Rejection
At 20MHz
At > 40MHz
RXHP = 1 (used before AGC completion)
Baseband Highpass Filter
Corner Frequency
RXHP = 0 (used after
AGC completion)
address A4:A0 = 01110
D5:D4 = 00
D5:D4 = 01
D5:D4 = 10
D5:D4 = 11
TYP
-37
-29
-21
-4
2.5
MAX UNITS
dBm
VP-P
-11
-8
dBm
-6
+16
0.15
Degrees
0.1
dB
10
k
5
pF
±1
mV/ms
±1
mV
0
+4.5
dB
57
75
dB
90
650
0.1
1
kHz
30
100
4 _______________________________________________________________________________________

Share Link: 