±15kV ESD-Protected, 32Mbps, 3V/5V,
Triple RS-422/RS-485 Receivers with Fault Detection
ELECTRICAL CHARACTERISTICS (continued)
(VCC = +3V to +5.5V, TA = TMIN to TMAX , unless otherwise noted. Typical values are at VCC = +5V and TA = +25°C.)
PARAMETER
SYMBOL
CONDITIONS
MIN TYP MAX
MAX3098EB Fault-Detection
Receiver Differential Threshold
Voltage (Note 3)
FDIFH
FDIFL
VCM = 0
High limit
70
250
Low limit
-250
-70
Fault-Detection Common-Mode
Voltage Range (Note 4)
DELAY Current Source
DELAY Threshold
ESD PROTECTION
ESD Protection
(A, A, B, B, Z, Z)
FCMH
FCML
High limit
Low limit
VCC = 5V, VDELAY = 0
VCC = 3V
VCC = 5V
Human Body Model
IEC1000-4-2 (Air-Gap Discharge)
IEC1000-4-2 (Contact Discharge)
13.2
-10
9
10
11
1.55 1.73 1.90
3.1 3.29 3.5
±15
±15
±8
UNITS
mV
V
µA
V
kV
SWITCHING CHARACTERISTICS
(VCC = +3V to +5.5V, VID = ±3.0V, TA = TMIN to TMAX, unless otherwise noted. Typical values are at VCC = +5V and TA = +25°C.)
PARAMETER
Propagation Delay from Input to
Output
Receiver Skew |tPLH - tPHL|
Channel-to-Channel
Propagation Delay Skew
Maximum Data Rate
FAULT DETECTION
SYMBOL
tPLH, tPHL
tSKEW
CONDITIONS
CL = 15pF,
Figures 1, 2
VCC = 4.5V to 5.5V
VCC = 3.0V to 3.6V
CL = 15pF, Figures 1, 2
CL = 15pF, Figures 1, 2
fMAX CL = 15pF, Figure 1
MIN TYP MAX UNITS
75
ns
85
±10
ns
±10
ns
32
Mbps
Differential Fault Propagation
Delay to Output (Note 5)
tDFLH
tDFHL
CLF = 15pF, Figures 1, 3
15
µs
1.2
Minimum Differential Slew Rate
to Avoid False Alarm Output
MAX3097E (Note 6)
MAX3098E (Note 7)
1.0
V/µs
0.33
Common-Mode Fault
Propagation Delay to Output
(Note 5)
tCMFLH
tCMFHL
CL = 15pF, Figures 1, 4
15
µs
1.5
Note 1: VCM is the common-mode input voltage. VID is the differential input voltage.
Note 2: VIN is the input voltage at pins A, A, B, B, Z, Z.
Note 3: A differential terminating resistor is required for proper function of open-circuit fault detection (see Applications Information).
Note 4: See Applications Information for a discussion of the receiver common-mode voltage range and the operating conditions for
fault indication.
Note 5: Applies to the individual channel immediate-fault outputs (ALARM_) and the general delayed-fault output (ALARMD) when
there is no external capacitor at DELAY.
Note 6: Equivalent pulse test: 1.3V / (tDFLH - tDFHL) SRD.
Note 7: Equivalent pulse test: 0.62V / (tDFLH - tDFHL) SRD.