±15kV ESD-Protected, 32Mbps, 3V/5V,
Triple RS-422/RS-485 Receivers with Fault Detection
Table 1. MAX3097E Alarm Function Table (Each Receiver)
INPUTS
OUTPUTS
VID
(DIFFERENTIAL
INPUT VOLTAGE)
COMMON-MODE
VOLTAGE
OUT_
ALARM_
ALARMD
t DELAY
(NOTE 1)
0.475V
<0.475V and 0.275V
1
0
0
1
Indeterminate Indeterminate
<0.275V and 0.2V
1
1
1
0.2V and -0.2V
-0.2V and >-0.275V
-0.275V and
>-0.475V
-0.475V
X
13.2V and -10V
<-10V or >+13.2V
Indeterminate
(Note 2)
0
0
0
Indeterminate
(Note 3)
1
1
Indeterminate
0
1
1
1
Indeterminate
0
1
X = Dont care
Note 1: ALARMD indicates fault for any receiver.
Note 2: Receiver output may oscillate with this differential input condition.
Note 3: See Applications Information for conditions leading to input range fault condition.
FAULT CONDITION
Normal Operation
Indeterminate
Low Input Differential Voltage
Low Input Differential Voltage
Low Input Differential Voltage
Indeterminate
Outside Common-Mode
Voltage Range
Table 2. MAX3098EA Alarm Function Table (Each Receiver)
INPUTS
VID
(DIFFERENTIAL
INPUT VOLTAGE)
COMMON-MODE
VOLTAGE
0.2V
<0.2V and 0.12V
<0.12V and -0.12V
13.2V and -
10V
-0.12V and -0.2V
-0.2V
OUT_
1
Indeterminate
Indeterminate
(Note 2)
Indeterminate
0
OUTPUTS
ALARM_
0
Indeterminate
1
Indeterminate
0
ALARMD
t DELAY
(NOTE 1)
0
Indeterminate
1
Indeterminate
0
FAULT CONDITION
Normal Operation
Indeterminate
Low Input Differential Voltage
Indeterminate
Normal Operation
X
<-10V or
>+13.2V
Indeterminate
(Note 3)
1
Outside Common-Mode Voltage
1
Range
X = Dont care; for B-grade functionality, replace VID input values in Table 2 with B-grade parameters from Electrical Characteristics.
Note 1: ALARMD indicates fault for any receiver.
Note 2: Receiver output may oscillate with this differential input condition.
Note 3: See Applications Information for conditions leading to input range fault condition.