10, Quad, SPST, CMOS Analog Switches
ELECTRICAL CHARACTERISTICS—Single Supply
(V+ = 12V, V- = 0V, VL = 5V, GND = 0V, VINH = 2.4V, VINL = 0.8V, TA = TMIN to TMAX, unless otherwise noted.)
PARAMETER
SYMBOL
CONDITIONS
ANALOG SWITCH
Analog Signal Range
Channel On-Resistance
POWER SUPPLY
Positive Supply Current
Logic Supply Current
Ground Current
DYNAMIC
Turn-On Time
(Note 3)
Turn-Off Time
(Note 3)
Break-Before-Make Time Delay
(Note 3)
Charge Injection
(Note 3)
VCOM_,
VNO_,
VNC_
RON
(Note 3)
ICOM = 10mA,
VNC_ or VNO_ +10V
TA = +25°C
TA = TMIN to TMAX
I+
IL
IGND
V+ = 13.2V
all channels on or off,
VIN = 0V or 5V
VL = 5.5V
all channels on or off,
VIN = 0V or 5V
VL = 5.5V
all channels on or off,
VIN = 0V or 5V
TA = +25°C
TA = TMAX
TA = +25°C
TA = TMAX
TA = +25°C
TA = TMAX
tON
tOFF
tD
VCTE
Figure 2,
VNO_ or VNC_ = 8V
Figure 2,
VNO_ or VNC_ = 8V
MAX314 only, Figure 3
RL = 300,
CL = 35pF
Figure 4,
CL = 1.0nF,
VGEN = 0V,
RGEN = 0V
TA = +25°C
TA = TMIN to TMAX
TA = +25°C
TA = TMIN to TMAX
TA = +25°C
TA = +25°C
MIN TYP MAX
(Note 2)
UNITS
0
V+
V
12.5
25
35
-1 0.0001 1
µA
-5
5
-1 0.0001 1
µA
-5
5
-1 -0.0001 1
µA
-5
5
100
325
ns
425
95
175
ns
225
5
ns
-5
pC
Note 2: The algebraic convention, where the most negative value is a minimum and the most positive value a maximum, is used in
this data sheet.
Note 3: Guaranteed by design.
Note 4: RON = RON max - RON min.
Note 5: Flatness is defined as the difference between the maximum and minimum value of on-resistance as measured over the
specified analog signal range.
Note 6: Leakage parameters are 100% tested at maximum-rated hot temperature and guaranteed by correlation at +25°C.
Note 7: Off isolation = 20log10 [VCOM / (VNC or VNO)], VCOM = output, VNC or VNO = input to off switch.
Note 8: Between any two switches.
Note 9: Leakage testing at single supply is guaranteed by testing with dual supplies.