MAX519BCSE Datasheet PDF : 16 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
2-Wire Serial 8-Bit DACs with
Rail-to-Rail Outputs
11
or or
0 1 0 AD3 AD2AD1 AD0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 0
SDA
ADDRESS BYTE
START
CONDITION
ACK
COMMAND BYTE
ACK
(ADDRESSING DAC0)
OUTPUT BYTE
ACK
(FULL SCALE)
STOP
( ) DAC0 INPUT LATCH CONDITION
SET TO FULL SCALE
( ) DAC OUTPUT CHANGES HERE:
DAC0 GOES TO FULL SCALE.
Figure 8a. Setting One DAC Output (MAX517/MAX518/MAX519)
11
or or
0 1 0 AD3 AD2AD1 AD0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 0 0 0 0 0 0 0 0 1 0
SDA
ADDRESS BYTE
START
CONDITION
ACK
COMMAND BYTE
ACK
(ADDRESSING DAC0)
OUTPUT BYTE
ACK
COMMAND BYTE
ACK
(FULL SCALE)
(ADDRESSING DAC1)
( ) DAC0 INPUT LATCH
SET TO FULL SCALE
11111111 0
SDA
OUTPUT BYTE
ACK
(FULL SCALE)
STOP
( ) DAC1 INPUT LATCH CONDITION
SET TO FULL SCALE
( ) DAC OUTPUTS CHANGE HERE:
DAC0 AND DAC1 GO TO FULL SCALE.
Figure 8b. Setting Both DAC Outputs (MAX518/MAX519)
11
(a)
or or
(PD)
0 1 0 AD3 AD2 AD1 AD0 0 0 0 0 0 0 1
0
SDA
XXX
START
CONDITION
ADDRESS BYTE
ACK
COMMAND BYTE
ACK
( ) STOP DEVICE ENTERS
CONDITION POWER-DOWN STATE
11
(b)
or or
(PD)
0 1 0 AD3 AD2 AD1AD0 0 0 0 0 0 0 1
0 0 111111110
SDA
XX
START
CONDITION
ADDRESS BYTE
NOTE: X = DON'T CARE
ACK
COMMAND BYTE
ACK
(ADDRESSING DAC0)
OUTPUT BYTE
ACK
(FULL SCALE)
STOP
DAC0 INPUT LATCH CONDITION
( ) SET TO FULL SCALE. DEVICE ENTERS POWER-DOWN STATE.
( ) DAC0 OUTPUT LATCH SET TO FULL SCALE.
Figure 9. Entering the Power-Down State
10 ______________________________________________________________________________________