DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

MAX5904(2003) データシートの表示(PDF) - Maxim Integrated

部品番号
コンポーネント説明
メーカー
MAX5904 Datasheet PDF : 22 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
Low-Voltage, Dual Hot-Swap Controllers/Power
Sequencers
ELECTRICAL CHARACTERISTICS (continued)
(VIN_ = +1V to +13.2V provided at least one supply is higher than +2.7V, VON = +2.7V, TA = TMIN to TMAX, unless otherwise noted.
Typical values are at VIN1 = +5V, VIN2 = +3.3V, and TA = +25°C.) (Note 1)
PARAMETER
SYMBOL
CONDITIONS
MIN TYP MAX UNITS
Channel 1 ON Threshold
Channel 2 ON Threshold
ON Propagation Delay
ON Input Bias Current
ON Pulse Width Low
DIGITAL OUTPUT (PGOOD)
Low to high
VON1,TH
Hysteresis
Low to high
VON2,TH
Hysteresis
tON 10mV overdrive
VON < 4.5V
IBON VIN1 = VIN2 = +13.2V VON > 4.5V
VON = 4V
tUNLATCH To unlatch after a latched fault
0.80 0.825 0.85
V
25
mV
1.95 2.025 2.07
V
25
mV
50
µs
0.03
100
µA
0.03
1
100
µs
Output Leakage Current
VPGOOD = 13.2V
Output Voltage Low
PGOOD Delay
VOL
tPGDLY
ISINK = 1mA
After tSTART, MON_ = VIN_
OUTPUT VOLTAGE MONITORS (MON1, MON2)
MON_ Trip Threshold
Overvoltage
VMON_ Undervoltage
MON_ Glitch Filter
1
µA
0.4
V
0.75
ms
657 687
707
mV
513 543
563
20
µs
MON_ Input Bias Current
UNDERVOLTAGE LOCKOUT (UVLO)
VMON_ = 600mV
0.03
µA
UVLO Threshold
Startup is initiated when this threshold is reached
VUVLO by VIN1 or VIN2, VON > 0.8V, VIN_ increasing
2.1
2.4
2.67
V
Hysteresis
100
mV
UVLO Glitch Filter Reset Time
UVLO to Startup Delay
SHUTDOWN RESTART
VIN_ = 0V, to unlatch after a fault
tD,UVLO VIN_ step from 0 to 2.8V
100
µs
20
37.5
60
ms
Auto-Retry Delay
tRETRY
Delay time to restart after a fault shutdown
MAX5904/MAX5906/MAX5908
64 x tSTART
ms
UNCOMMITTED COMPARATOR
INC+ Trip Threshold Voltage
Propagation Delay
OUTC Voltage Low
INC+ Bias Current
OUTC Leakage Current
VC,TH
VOL
IOUTC
Low to high
Hysteresis
10mV overdrive
ISINK = 1mA
VINC+ = 5V
VOUTC = 13.2V
1.206 1.236 1.266
V
10
mV
50
µs
0.4
V
0.02
1
µA
0.02
1
µA
Note 1: Limits are 100% tested at TA = +25°C and +85°C. Limits at 0°C and -40° are guaranteed by characterization and are not produc-
tion tested.
Note 2 The MAX5906MAX5909 slow-comparator threshold is adjustable. VSC,TH = RLIM x 0.25µA + 25mV (see Typical Operating
Characteristics).
Note 3: The current-limit slow-comparator response time is weighted against the amount of overcurrent; the higher the overcurrent
condition, the faster the response time. See Typical Operating Characteristics.
Note 4: The startup period (tSTART) is the time during which the slow comparator is ignored and the device acts as a current limiter
by regulating the sense current with the fast comparator. See the Startup Period section.
_______________________________________________________________________________________ 3