MC10E131, MC100E131
Table 4. 10E SERIES NECL DC CHARACTERISTICS VCCx = 0.0 V; VEE = −5.0 V (Note 3)
−40°C
0°C
25°C
85°C
Symbol Characteristic Min Typ Max Min Typ Max Min Typ Max Min Typ Max Unit
IEE
Power Supply Cur-
rent
58 70
58
70
58
70
58
70 mA
VOH
Output HIGH Volt-
age (Note 4)
−1020 −930 −840 −980 −895 −810 −910 −815 −720 mV
VOL
Output LOW Volt-
age (Note 4)
−1950 −1790 −1630 −1950 −1790 −1630 −1950 −1773 −1595 mV
VIH
Input HIGH Voltage
VIL
Input LOW Voltage
IIH
Input HIGH Current
CC
S
R, CE
D
IIL
Input LOW Current
−1170 −1005 −840 −1130 −970 −810 −1060 −890 −720 mV
−1950 −1715 −1480 −1950 −1715 −1480 −1950 −1698 −1445 mV
mA
350
350
350
350
450
450
450
450
300
300
300
300
150
150
150
150
0.5 0.3
0.5 0.065
0.3 0.2
mA
NOTE: Device will meet the specifications after thermal equilibrium has been established when mounted in a test socket or printed circuit
board with maintained transverse airflow greater than 500 lfpm. Electrical parameters are guaranteed only over the declared
operating temperature range. Functional operation of the device exceeding these conditions is not implied. Device specification limit
values are applied individually under normal operating conditions and not valid simultaneously.
3. Input and output parameters vary 1:1 with VCC. VEE can vary −0.46 V / +0.06 V.
4. Outputs are terminated through a 50 W resistor to VCC − 2.0 V.
Table 5. 100E SERIES PECL DC CHARACTERISTICS VCCx = 5.0 V; VEE = 0.0 V (Note 5)
−40°C
0°C
25°C
85°C
Symbol
IEE
VOH
Characteristic
Power Supply Current
Output HIGH Voltage
(Note 6)
Min Typ Max Min Typ Max Min Typ Max Min Typ Max Unit
58 70
58 70
58 70
67 81 mA
3975 4050 4120 3975 4050 4120 3975 4050 4120 mV
VOL
Output LOW Voltage
(Note 6)
3190 3295 3380 3190 3255 3380 3190 3260 3380 mV
VIH
Input HIGH Voltage
VIL
Input LOW Voltage
IIH
Input HIGH Current CC
S
R, CE
D
3975
3835 3975 4120 3835 3975 4120 3835 3975 4120 mV
3355
3190 3355 3525 3190 3355 3525 3190 3355 3525 mV
350
350
350
350 mA
450
450
450
450
300
300
300
300
150
150
150
150
IIL
Input LOW Current
0.5 0.3
0.5 0.25
0.5 0.2
mA
NOTE: Device will meet the specifications after thermal equilibrium has been established when mounted in a test socket or printed circuit
board with maintained transverse airflow greater than 500 lfpm. Electrical parameters are guaranteed only over the declared
operating temperature range. Functional operation of the device exceeding these conditions is not implied. Device specification limit
values are applied individually under normal operating conditions and not valid simultaneously.
5. Input and output parameters vary 1:1 with VCC. VEE can vary −0.46 V / +0.8 V.
6. Outputs are terminated through a 50 W resistor to VCC − 2.0 V.
http://onsemi.com
4