MC100LVEL90
Table 3. NECL INPUT DC CHARACTERISTICS VCC= 3.3 V; VEE= 3.3 V; GND= 0 V (Note 1)
40°C
25°C
85°C
Symbol
Characteristic
Min Typ Max
Min Typ Max
Min Typ Max Unit
IEE
VIH
VIL
ECL VBB
VIHCMR
VEE Power Supply Current
Input HIGH Voltage (SingleEnded)
1165
Input LOW Voltage (SingleEnded) 1810
Output Voltage Reference
1.38
Input HIGH Voltage Common Mode
Range (Differential) (Note 2)
Vpp < 500 mV
Vpp y 500 mV
VEE+1.3
VEE+1.5
8.0
880
1475
1.26
1165
1810
1.38
6.0 8.0
880
1475
1.26
1165
1810
1.38
0.4 VEE+1.2
0.4 VEE+1.4
0.4 VEE+1.2
0.4 VEE+1.4
8.0 mA
880 mV
1475 mV
1.26 V
0.4 V
0.4 V
IIH
Input HIGH Current
IIL
Input LOW Current
D 0.5
D 600
150
0.5
600
150
0.5
600
150 mA
mA
NOTE: Device will meet the specifications after thermal equilibrium has been established when mounted in a test socket or printed circuit
board with maintained transverse airflow greater than 500 lfpm. Electrical parameters are guaranteed only over the declared
operating temperature range. Functional operation of the device exceeding these conditions is not implied. Device specification limit
values are applied individually under normal operating conditions and not valid simultaneously.
1. Input parameters vary 1:1 with GND. VEE can vary 3.0 V to 5.5 V.
2. VIHCMR min varies 1:1 with VEE. VIHCMR max varies 1:1 with GND.
Table 4. LVPECL OUTPUT DC CHARACTERISTICS VCC= 3.3 V; VEE= 3.3 V; GND= 0 V (Note 3)
40°C
25°C
85°C
Symbol
Characteristic
Min Typ Max Min Typ Max Min Typ Max Unit
ICC
VCC Power Supply Current
VOH
Output HIGH Voltage (Note 4)
VOL
Output LOW Voltage (Note 4)
24
20
24
26 mA
2215 2295 2420 2275 2345 2420 2275 2345 2420 mV
1470 1605 1745 1490 1600 1680 1490 1595 1680 mV
NOTE: Device will meet the specifications after thermal equilibrium has been established when mounted in a test socket or printed circuit
board with maintained transverse airflow greater than 500 lfpm. Electrical parameters are guaranteed only over the declared
operating temperature range. Functional operation of the device exceeding these conditions is not implied. Device specification limit
values are applied individually under normal operating conditions and not valid simultaneously.
3. Output parameters vary 1:1 with VCC. VCC can vary +0.5 V / 0.3 V. VEE can vary 3.0 V to 5.5 V.
4. Outputs are terminated through a 50 W resistor to VCC2 volts.