DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

ML9205-01GP データシートの表示(PDF) - Oki Electric Industry

部品番号
コンポーネント説明
メーカー
ML9205-01GP Datasheet PDF : 34 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
¡ Semiconductor
FEDL9205-02
ML9205-01
AC Characteristics-1
Parameter
CP Frequency
CP Pulse Width
DA Setup Time
DA Hold Time
CS Setup Time
CS Hold Time
CS Wait Time
Data Processing Time
RESET Pulse Width
RESET Time
DA Wait Time
All Output Slew Rate
VDD Rise Time
VDD Off Time
(VDD, VDISP=5.0V±10%, VFL=–60 V, Ta=–40 to +85°C, unless otherwise specified)
Symbol
Condition
Min. Max. Unit
fC
tCW
250
tDS
250
tDH
250
tCSS
250
tCSH
R1=3.3 kW, C1=47 pF
16
tCSW
250
tDOFF
R1=3.3 kW, C1=47 pF
8
When RESET signal is input from
tWRES
microcontroller, etc. externally
250
When RESET signal is input from
tRSON
microcontroller, etc. externally
250
R2=1.0 kW, C2=0.1 mF
tRSOFF
250
tR
tF
Cl=100pF
tR=20% to 80%
tF=80% to 20%
tPRZ
When mounted in the unit
tPOF When mounted in the unit, VDD=0.0 V
5.0
2.0 MHz
ns
ns
ns
ns
ms
ns
ms
ns
ns
200 ms
ns
2.0
ms
2.0
ms
100 ms
ms
AC Characteristics-2
Parameter
CP Frequency
CP Pulse Width
DA Setup Time
DA Hold Time
CS Setup Time
CS Hold Time
CS Wait Time
Data Processing Time
RESET Pulse Width
RESET Time
DA Wait Time
All Output Slew Rate
VDD Rise Time
VDD Off Time
(VDD, VDISP=3.3V±10%, VFL=–60V, Ta=–40 to +85°C, unless otherwise specified)
Symbol
Condition
Min. Max. Unit
fC
tCW
250
tDS
250
tDH
250
tCSS
250
tCSH
R1=3.3 kW, C1=39 pF
16
tCSW
250
tDOFF
R1=3.3 kW, C1=39 pF
8
When RESET signal is input from
tWRES
microcontroller etc. externally
250
tRSON
When RESET signal is input from
microcontroller etc. externally
250
R2=1.0 kW, C2=0.1 mF
tRSOFF
250
tR
tF
Cl=100pF
tR=20% to 80%
tF=80% to 20%
tPRZ
When mounted in the unit
tPOF When mounted in the unit, VDD=0.0 V
5.0
2.0 MHz
ns
ns
ns
ns
ms
ns
ms
ns
ns
200 ms
ns
2.0
ms
2.0
ms
100 ms
ms
10/34

Share Link: 

datasheetq.com  [ Privacy Policy ]Request Datasheet ] [ Contact Us ]