MICRF005
Polarity of the droop is unknown, meaning the AGC voltage
could droop up or down. Worst-case from a recovery stand-
point is downward droop, since the AGC pullup current is
1/10th magnitude of the pulldown current. The downward
droop is replenished according to the Equation (6):
(6)
I = V
CAGC t
where:
I = AGC pullup current for the initial [tbd]ms (67.5µA)
CAGC = AGC capacitor value
t = droop recovery time
V = droop voltage
Micrel
For example, if user desires t = 10ms and chooses a 4.7µF
CAGC, then the allowable droop is about 144mV. Using the
same equation with 200nA worst case pin leakage and
assuming 1µA of capacitor leakage in the same direction, the
maximum allowable t (shutdown time) is about 0.56s for
droop recovery in 10ms.