Powerex, Inc., 200 E. Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272
PS21562
Intellimod™ Module
Dual-In-Line Intelligent Power Module
5 Amperes/600 Volts
Electrical and Mechanical Characteristics, Tj = 25°C unless otherwise specified
Characteristics
Symbol
Test Conditions
Min.
Typ. Max. Units
Control Sector
Control Supply Voltage
VD
Applied between VP1-VNC, VN1-VNC
13.5 15.0 16.5 Volts
VDB
Applied between VUFB-VUFS,
13.0 15.0 18.5 Volts
VVFB-VVFS, VWFB-VWFS
Circuit Current
ID
VD = VDB = 15V, VIN = 5V,
—
—
5.00
mA
Total of VP1-VNC, VN1-VNC
VD = VDB = 15V, VIN = 0V,
—
—
7.00
mA
Total of VP1-VNC, VN1-VNC
VD = VDB = 15V, VIN = 5V,
—
—
0.40
mA
VUFB-VUFS, VVFB-VVFS, VWFB-VWFS
VD = VDB = 15V, VIN = 0V,
—
—
0.55
mA
VUFB-VUFS, VVFB-VVFS, VWFB-VWFS
Fault Output Voltage
VFOH
VSC = 0V, FO Circuit: 10k Ω to 5V Pull-up
4.9
—
—
Volts
VFOL
VSC = 1V, IFO = 1mA
—
—
0.95 Volts
Input Current
IIN
VIN = 5V
1.0
1.50 2.00
mA
PWM Input Frequency
fPWM
Tf ≤ 100°C, Tj ≤ 125°C
—
10
—
kHz
Short Circuit Trip Level*
VSC(ref)
Tj = 25°C, VD = 15V
0.43 0.48 0.53 Volts
Supply Circuit Under-voltage
UVDBt
Trip Level, Tj ≤ 125°C
10.0
—
12.0 Volts
Protection
UVDBr
Reset Level, Tj ≤ 125°C
10.5
—
12.5 Volts
UVDt
Trip Level, Tj ≤ 125°C
10.3
—
12.5 Volts
UVDr
Reset Level, Tj ≤ 125°C
10.8
—
13.0 Volts
Fault Output Pulse Width**
tFO
CFO = 22nF
1.0
1.8
—
ms
ON Threshold Voltage
Vth(on)
Applied between UP, VP, WP-VNC,
2.1
2.3
2.6
Volts
OFF Threshold Voltage
Vth(off)
UN, VN, WN-VNC
0.8
1.4
2.1
Volts
* Short Circuit protection is functioning only at the lower arms. Please select the value of the external shunt resistor such that the SC trip level is less than 8.5A.
**Fault signal is asserted when the lower arm short circuit or control supply under-voltage protective functions operate. The fault output pulse-width tFO depends on the capacitance value of
CFO according to the following approximate equation: CFO = (12.2 x 10-6) x tFO {F} .
4