DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

L6605(2001) データシートの表示(PDF) - Hamamatsu Photonics

部品番号
コンポーネント説明
メーカー
L6605
(Rev.:2001)
Hamamatsu
Hamamatsu Photonics Hamamatsu
L6605 Datasheet PDF : 4 Pages
1 2 3 4
RELATED PRODUCTS
Trigger Socket E6647
In order to operate a Xenon flash lamp, it is necessary to supply the prescribed high voltage between anode and
cathode, and to trigger probes. To facilitate the above operation, the trigger socket consists of high voltage
transformer and voltage divider resistors and capacitors chain to supply the appropriate pulse voltage to each
electrode.
As E6647 radiates heat from its metal parts during the operation due to the input energy, it is recommended to
use a cooling fan to keep the surface temperature of the metal parts at less than 50 °C.
Dimensional Outline (Unit: mm)
14.8±0.1
METAL
RED : MAIN DISCHAGE VOLTAGE
WHITE : TRIGGER VOLTAGE
BLACK : GND (MAIN)
BROWN : GND (TRIGGER)
5.5
28.5±1.0
73.5±2.0
500±20
TLSXA0050EB
Power Supply C6096
C6096 has large capability to operate the lamp stable in spite of its compact dimensions. At 1 J/flash input energy
becomes over 0.05 J, it is necessary to have an additional external capacitor E7289-01 (option).
Specifications
Dimensional Outline (Unit: mm)
Parameter
Description/Value
Main
Power
Supply
Output Voltage g h (dc)
Output Capacity
Stability
Main Supply Capacitor i
300 V to 1000 V
60 W Max.
±1 % Max.
0.1 µF
Trigger Trigger Output Voltage
Section Trigger Capacitor
180 V Typ.
0.22 µF
Trigger Type
Internal / External
Trigger Repetition Rate j
Input Trigger Input Impedance
Section Input Waveform k
10 Hz to 100 Hz
1 k
Rectangular Waveform
Input Voltage
5V
Input Voltage (dc)
24 V ± 1.2 V
Power Consumption
Cooling
90 W
Not Required
Weight
Approx. 550 g
NOTE: g The range of 700 V to 1000 V is used for the operation
of 60 W Xenon flash lamp series.
h In the case of connects temperature sensor lead lines
from the cooling jacket, the output voltage becomes 0 V
when the temperature sensor turns on.
i At 1 J/flash input energy becomes over 0.05 J, it is
necessary to have an additional external capacitor
E7289-01 (option).
j Dont use beyond 60 Hz at the operation of 60 W input.
k A trigger pulse voltage is supplied to each electrode at
the same time as an input trigger signal rise.
2-M3
108±2
80.0±0.5
14
174±3
100.0±0.5
2-M3
TLSXA0051EA

Share Link: 

datasheetq.com  [ Privacy Policy ]Request Datasheet ] [ Contact Us ]