MSM7541 データシートの表示(PDF) - Oki Electric Industry

部品番号
コンポーネント説明
メーカー
MSM7541
OKI
Oki Electric Industry OKI
MSM7541 Datasheet PDF : 20 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
¡ Semiconductor
MSM7541/7542
PIN AND FUNCTIONAL DESCRIPTIONS
AIN+, AIN–, GSX
Transmit analog input and transmit level adjustment.
AIN+ is a non-inverting input to the op-amp; AIN– is an inverting input to the op-amp; GSX is
connected to the output of the op-amp and is used to adjust the level, as shown below.
When not using AIN– and AIN+, connect AIN– to GSX and AIN+ to SG. During power saving
and power down modes, the GSX output is at AG voltage.
1) Inverting input type
Analog input
C1
R1
GSX
R2
AIN–
AIN+
SG
+
R1 : variable
R2 > 20 kW
C1 > 1/(2 ¥ 3.14 ¥ 30 ¥ R1)
Gain = R2/R1 £ 10
2) Non inverting input type
C2
Analog input
R5
R4
R3
AIN+
AIN–
+
GSX
SG
R3 > 20 kW
R4 > 20 kW
R5 > 50 kW
C2 > 1/ (2 ¥ 3.14 ¥ 30 ¥ R5)
Gain = 1 + R4 / R3 £ 10
AG
Analog signal ground.
VFRO
Receive filter output.
The output signal has an amplitude of 2.0 VPP above and below the signal ground voltage (SG)
when the digital signal of +3 dBmO is input to PCMIN and can drive a load of 20 kW or more.
For driving a load of 20 kW or less, the output signal of AOUT+ and AOUT– is available.
To apply the output signal of AOUT+ and AOUT– for driving, connect a resistor of 20 kW or more
between the pins VFRO and PWI.
When adding the frequency characteristics to the receive signal, refer to the application example.
During power saving or power down mode, the output of VFRO is at the voltage level of AG.