DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

MX29F022 データシートの表示(PDF) - Macronix International

部品番号
コンポーネント説明
メーカー
MX29F022
MCNIX
Macronix International MCNIX
MX29F022 Datasheet PDF : 46 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
MX29F022/022NT/B
TABLE 1. SOFTWARE COMMAND DEFINITIONS
First Bus Second Bus Third Bus Fourth Bus Fifth Bus Sixth Bus
Command
Bus Cycle
Cycle
Cycle
Cycle
Cycle
Cycle
Cycle Addr Data Addr Data Addr Data Addr Data Addr Data Addr Data
Reset
1 XXXH F0H
Read
1 RA RD
Read Silicon ID
4 555H AAH 2AAH 55H 555H 90H ADI DDI
Chip Protect Verify
4 555H AAH 2AAH 55H 555H 90H (SA) 00H
X02H 01H
Program
4 555H AAH 2AAH 55H 555H A0H PA PD
Chip Erase
6 555H AAH 2AAH 55H 555H 80H 555H AAH 2AAH 55H 555H 10H
Sector Erase
6 555H AAH 2AAH 55H 555H 80H 555H AAH 2AAH 55H SA 30H
Sector Erase Suspend 1 XXXH B0H
Sector Erase Resume 1 XXXH 30H
Unlock for chip
6 555H AAH 2AAH 55H 555H 80H 555H AAH 2AAH 55H 555H 20H
protect/unprotect
Note:
1. ADI = Address of Device identifier; A1=0,A0 =0 for manufacture code,A1=0, A0 =1 for device code (Refer to Table
3).
DDI = Data of Device identifier : C2H for manufacture code, 36H/37H for device code.
X = X can be VIL or VIH
RA=Address of memory location to be read.
RD=Data to be read at location RA.
2. PA = Address of memory location to be programmed.
PD = Data to be programmed at location PA.
SA = Address to the sector to be erased.
3. The system should generate the following address patterns: 555H or 2AAH to Address A0~A10.
Address bit A11~A17=X=Don't care for all address commands except for Program Address (PA) and Sector
Address (SA). Write Sequence may be initiated with A11~A17 in either state.
4. For Chip Protect Verify operation: If read out data is 01H, it means the chip has been protected. If read out data is
00H, it means the chip is still not being protected.
P/N:PM0556
REV. 1.3, NOV. 11, 2002
5

Share Link: 