GENERAL SPECIFICATIONS
All specifications are typical at nominal line, full load, and 25°C.
Efficiency:
75% minimum
Switching frequency:
80 kHz
Hi-pot isolation:
3750 VAC from input to output
Line regulation:
±0.5% (See note 3)
Load regulation:
±1% for outputs 1 and 3; ±3%
for output 2 (See note 4)
Cross regulation:
±4% for output 2; ±1% for output 3
(See note 5)
Operating temperature: 0°C to +70°C
Derating (50°C to 70°C): 2%/°C
Temperature coefficient: ±0.02%/°C
Storage temperature:
-40°C to +85°C
Humidity, non-condensing: 0 to 95% RH
EMI filter (on board):
Meets VDE/FCC Class B
conducted emission limits.
INPUT SPECIFICATIONS
Input voltage:
Input frequency:
Inrush current:
Hold-up time:
90 to 264 VAC
47 to 63 Hz
40A max. (cold start)
16ms
OUTPUT SPECIFICATIONS
Voltage adjustment:
+5VDC primary output (V1) Adjustable ±5%
Auxiliary output (V2,V3) Fixed ±5% (See note 2)
Total output power:
Convection cooled single output 65W
Convection cooled triple output 55W
Forced air triple output
65W @ 20CFM
Design topology:
Flyback
Overvoltage protecton: Main output only
Overload protection: 120 to 200% of rated value
Short circuit protection: Continuous
Ripple and noise:
1% peak-peak max. (See note 6)
MECHANICAL SPECIFICATIONS
CN1 INPUT CONNECTOR MOLEX 09-50-3031 WITH SECOND PIN REMOVED
CN2 OUTPUT CONNECTOR MOLEX 09-50-3061
MOLEX MATING CONNECTOR MOLEX 2139 SERIES
HOUSING WITH 2478 SERIES CRIMP TERMINALS
CN3 INPUT GROUND TAB. TAB SIZE 4.8 x 0.5(mm)
PIN CHART
NOTES:
1. Replace input line fuse with the same type and rating. Recommended
fuse is 3A/250VAC slo-blo.
2. Output tolerance is measured by setting the +5V output to its exact value
(ie 5.000V). With the power supply output loaded as follows: +5V/6A,
+12V/2.5A, +24V/1.25A, -12V/0.5A or -5V/0.5A any adjustment on the
+5V will cause the auxillary outputs to rise or fall proportionally.
3. Line regulation is measured at nominal load and the input voltage varied
from 90-132 VAC or 180-260 VAC.
4. Load regulation is measured at 115 VAC or 230 VAC input. The output
being measured is varied from 30% to 100% of full load. All other outputs
are loaded to 50% of full load.
5. Cross regulation is measured with a +5V at 6A load. Note: The effects of
load and cross regulation are not cumulative and may actually act to
cancel each other in an operating system environment.
6. Peak-to-peak and RMS metering equipment shall have a 20MHz response
with probes and cables maintaining frequency response from 200Hz to
200MHz bandwidth. Output ripple and noise spikes are measured directly
at the output pins of the power supply without the use of the probe ground clip.
ALL DIMENSIONS IN INCHES (mm)
TOLERANCE .XX =+ 0.05
.XXX=+0.020
Model
PIN
1
2
3
4
5
6
UP0651S-XX
OUTPUT
#1
OUTPUT
#1
OUTPUT
#1
COMMON COMMON
COMMON
UP0653S-XX
OUTPUT
#2
OUTPUT
#1
OUTPUT
#1
COMMON COMMON
COMMON
#3
International
Power Sources, Inc.
Your Source of Power ...
260 Hopping Brook Road, Holliston, MA 01746
TEL: (508) 429-4440 FAX: (800) 226-2100
69
http://www.intlpower.com

Share Link: 

datasheetq.com  [ Privacy Policy ]Request Datasheet ] [ Contact Us ]