NL37WZ17
MAXIMUM RATINGS
Symbol
Parameter
Value
Unit
VCC
VI
VO
IIK
IOK
IO
ICC
IGND
TSTG
TL
TJ
qJA
PD
MSL
DC Supply Voltage
DC Input Voltage
DC Output Voltage
Output in Z or LOW State (Note 1)
DC Input Diode Current
DC Output Diode Current
DC Output Sink Current
VI < GND
VO < GND
DC Supply Current per Supply Pin
DC Ground Current per Ground Pin
Storage Temperature Range
Lead Temperature, 1 mm from Case for 10 Seconds
Junction Temperature under Bias
Thermal Resistance
(Note 2)
Power Dissipation in Still Air at 85°C
Moisture Sensitivity
*0.5 to )7.0
*0.5 VI )7.0
*0.5 VO 7.0
*50
*50
$50
$100
$100
*65 to )150
260
)150
333
200
Level 1
V
V
V
mA
mA
mA
mA
mA
°C
°C
°C
°C/W
mW
FR
VESD
Flammability Rating
ESD Withstand Voltage
Oxygen Index: 28 to 34
UL 94 V−0 @ 0.125 in
Human Body Model (Note 3)
> 2000
V
Machine Model (Note 4)
> 200
Charged Device Model (Note 5)
N/A
Stresses exceeding Maximum Ratings may damage the device. Maximum Ratings are stress ratings only. Functional operation above the
Recommended Operating Conditions is not implied. Extended exposure to stresses above the Recommended Operating Conditions may affect
device reliability.
1. IO absolute maximum rating must be observed.
2. Measured with minimum pad spacing on an FR4 board, using 10 mm−by−1 inch, 2−ounce copper trace with no air flow.
3. Tested to EIA/JESD22−A114−A.
4. Tested to EIA/JESD22−A115−A.
5. Tested to JESD22−C101−A.
RECOMMENDED OPERATING CONDITIONS
Symbol
Parameter
Min
Max
VCC
Supply Voltage
Operating
2.3
5.5
Data Retention Only
1.5
5.5
VI
Input Voltage
(Note 6)
0
5.5
VO
Output Voltage
(HIGH or LOW State)
0
5.5
TA
Operating Free−Air Temperature
*40
)85
Dt/DV
Input Transition Rise or Fall Rate
VCC = 2.5 V $0.2 V
0
VCC = 3.0 V $0.3 V
0
VCC = 5.0 V $0.5 V
0
No Limit
No Limit
No Limit
6. Unused inputs may not be left open. All inputs must be tied to a high−logic voltage level or a low−logic input voltage level.
Unit
V
V
V
°C
ns/V