NLAS2066
160
140
120
VCC = 2.0
100
80
60
VCC = 2.5
40
20
0
0
VCC = 3.0
1
2
VCC = 4.5
3
4
5
VIS (VOLTS)
Figure 2. RON vs. VCOM and VCC (@255C)
200
−40°C
25°C
150
85°C
100
125°C
50
0
0
0.5
1.0
1.5
2.0
VIS (VOLTS)
Figure 3. RON vs. VCOM and Temperature,
VCC = 2.0 V
30
−40°C
25°C
25
85°C
20
15
125°C
10
5
0
0
1.0
2.0
3.0
VIS (VOLTS)
Figure 4. RON vs. VCOM and Temperature,
VCC = 2.5 V
12
−40°C
10
8
6
25°C
85°C
4
125°C
2
0
0
1.0
2.0
3.0
4.0
VIS (VOLTS)
Figure 5. RON vs. VCOM and Temperature,
VCC = 3.0 V
6
35.0
−40°C
5
85°C
25°C
30.0
4
25.0
20.0
3
125°C
15.0
2
tON
10.0
1
5.0
tOFF
0
0.0
0
1.0
2.0
3.0
4.0
5.0
2.0
3.0
4.5
5.0
5.5
VIS (VOLTS)
VCC (V)
Figure 6. RON vs. VCOM and Temperature,
VCC = 4.5 V
Figure 7. Switching Time vs. Supply Voltage,
T = 255C
http://onsemi.com
6