Philips Semiconductors Programmable Logic Devices
Programmable logic arrays
(18 × 42 × 10)
Product specification
PLS153/A
LOGIC FUNCTION
TYPICAL PRODUCT TERM:
Pn = A B C D . . .
TYPICAL LOGIC FUNCTION:
AT OUTPUT POLARITY = H
Z = P0 + P1 + P2 . . .
AT OUTPUT POLARITY = L
Z = P0 + P1 + P2 + . . .
Z = P0 P1 P2 . . .
NOTES:
1. For each of the 10 outputs, either function Z
(Active-High) or Z (Active-Low) is available, but not
both. The desired output polarity is programmed via
the Ex-OR gates.
2. Z, A, B, C, etc. are user defined connections to fixed
inputs (I) and bidirectional pins (B).
SP00275
THERMAL RATINGS
TEMPERATURE
Maximum junction
150°C
Maximum ambient
75°C
Allowable thermal rise
ambient to junction
75°C
The PLS153/A devices are also processed to
military requirements for operation over the
military temperature range. For specifications
and ordering information consult the Philips
Semiconductors Military Data Handbook.
DC ELECTRICAL CHARACTERISTICS
0°C Tamb +75°C, 4.75V VCC 5.25V
SYMBOL
PARAMETER
TEST CONDITIONS
Input voltage2
VIL
Low
VIH
High
VIC
Clamp3
Output voltage2
VCC = MIN
VCC = MAX
VCC = MIN, IIN = –12mA
VOL
Low4
VOH
High5
Input current9
VCC = MIN
IOL = 15mA
IOH = –2mA
IIL
Low
IIH
High
Output current
VCC = MAX
VIN = 0.45V
VIN = 5.5V
IO(OFF)
Hi-Z state8
IOS
Short circuit3, 5, 6
ICC
VCC supply current7
Capacitance
VCC = MAX
VOUT = 5.5V
VOUT = 0.45V
VOUT = 0V
VCC = MAX
VCC = 5V
CIN
Input
VIN = 2.0V
CB
I/O
VB = 2.0V
NOTES:
1. All typical values are at VCC = 5V, Tamb = +25°C.
2. All voltage values are with respect to network ground terminal.
3. Test one at a time.
4. Measured with +10V applied to I7.
5. Measured with +10V applied to I0–7. Output sink current is supplied through a resistor to VCC.
6. Duration of short circuit should not exceed 1 second.
7. ICC is measured with I0, I1 at 0V, I2 – I7 and B0–9 at 4.5V.
8. Leakage values are a combination of input and output leakage.
9. IIL and IIH limits are for dedicated inputs only (I0 – I7).
LIMITS
MIN TYP1 MAX
0.8
2.0
–0.8 –1.2
0.5
2.4
–100
40
80
–140
–15
–70
130
155
8
15
UNIT
V
V
V
V
V
µA
µA
µA
mA
mA
pF
pF