Electrical Specifications Typical values are at VDD = 1.2V, TA = +25°C, and VIN = 600mVP-P, unless otherwise noted.
VDD = 1.1V to 1.3V, TA = 0°C to +85°C. (Continued)
PARAMETER
SYMBOL
CONDITION
MIN TYP MAX UNITS NOTES
Output Return Loss
SDC22 100MHz to 7.5GHz
(Com. to Diff. Conversion)
32
dB
2
Output Residual
Deterministic Jitter
Output Residual
Deterministic Jitter
Output Transition Time
Propagation Delay
DJ
RJ
tr, tf
10Gb/s; Up to 10m 28AWG standard
twin-axial cable (approx. -27dB @ 5GHz);
1200mVP-P VIN 1600mVP-P
10Gb/s; Up to 10m 28AWG standard
twin-axial cable (approx. -27dB @ 5GHz);
1200mVP-P VIN 1600mVP-P
20% to 80%
From IN to OUT
0.15
UI
1, 3, 4
1.3
psRMS 1, 3, 4
35
ps
5
500
ps
LOS Assert Time
Time to assert Loss-of-Signal (LOS)
indicator when transitioning from active
data mode to line silence mode
50
µs
6
LOS De-Assert Time
Time to de-assert Loss-of-Signal (LOS)
indicator when transitioning from line
silence mode to active data mode
50
µs
6
Data-to-Line Silence
Response Time
Time to transition from active data to line
silence (muted output) on 10m 28AWG
standard twin-axial cable at 10Gb/s
50
µs
6
Line Silence-to-Data
Response Time
Time to transition from line silence mode
(muted output) to active data on 10m
28AWG standard twin-axial cable at 10Gb/s
50
µs
6
NOTES:
1. After channel loss, differential amplitudes at QLx111GRx input must meet the input voltage range specified in “Absolute
Maximum Ratings” on page 3.
2. Temperature = +25°C, VDD = 1.2V.
3. Output residual jitter is the difference between the total jitter at the lane extender output and the total jitter of the transmitted
signal (as measured at the input to the channel). Total jitter (TJ) is DJpp + 14.1 x RJRMS.
4. Measured using a PRBS 27-1 pattern. Deterministic jitter at the input to the lane extender is due to frequency-dependent,
media-induced loss only.
5. Rise and fall times measured using a 1GHz clock with a 20ps edge rate.
6. For active data mode, cable input amplitude is 300mVP-P (differential) or greater. For line silence mode, cable input amplitude
is 20mVP-P (differential) or less.
4