THERMAL CONSIDERATIONS
Thermal management is an important part of the system
design. To ensure proper, reliable operation, sufficient
cooling of the power module is needed over the entire
temperature range of the module. Convection cooling is
usually the dominant mode of heat transfer.
Hence, the choice of equipment to characterize the
thermal performance of the power module is a wind
tunnel.
Thermal Testing Setup
Delta’s DC/DC power modules are characterized in
heated vertical wind tunnels that simulate the thermal
environments encountered in most electronics
equipment. This type of equipment commonly uses
vertically mounted circuit cards in cabinet racks in which
the power modules are mounted.
The following figure shows the wind tunnel
characterization setup. The power module is mounted
on a test PWB and is vertically positioned within the
wind tunnel. The space between the neighboring PWB
and the top of the power module or a heat sink is
6.35mm (0.25”).
Thermal Derating
Heat can be removed by increasing airflow over the
module. Figure 19 shows maximum output is a function
of ambient temperature and airflow rate. To enhance
system reliability, the power module should always be
operated below the maximum operating temperature. If
the temperature exceeds the maximum module
temperature, reliability of the unit may be affected.
FACING PWB
PWB
MODULE
THERMAL CURVES
Figure 18: Hot spot temperature measured point
The allowed maximum hot spot temperature is defined at 102
S48SA1R212(Standard) Output Current vs. Ambient Temperature and Air Velocity
Output Current(A)
14
@ Vin = 48V (Either Orienation)
12
600LFM
10
Natural
Convection
8
100LFM
6
200LFM
4
2
300LFM
500LFM
400LFM
0
65
70
75
80
85
90
95
100
105
Ambient Temperature ()
AIR VELOCITY
AND AMBIENT
TEMPERATURE
MEASURED BELOW
THE MODULE
AIR FLOW
50.8 (2.0”)
Figure 19: Output current vs. ambient temperature and air velocity
@ Vin=48V
10 (0.4”)
Note: Wind Tunnel Test Setup Figure Dimensions are in millimeters and (Inches)
Figure 17: Wind tunnel test setup
9
DS_S48SA1R212_05122006