Signal Electrical Interface
Characteristic - Signal Name Symbol
Min
At remote/control ON/OFF pin
High level input current
Iih
Acceptable high level
leakage current
Low level input voltage
Iih (leakage)
ViI
0
High level input voltage
Vih
2.5
SIL05E Series | 5 A DC-DC Converter
E Class Non-Isolated
Typ
Max
500
-10
0.4
Units
µA
µA
V
V
Notes and Conditions
See Notes 2 and 3
Current flowing into control pin
when pin is pulled high
(max at Vih = 5.5V
Acceptable leakage current from
signal pin into the open collector
driver (neg = from converter)
Converter guaranteed ON
when control pin is less
than Vil (max)
Converter guaranteed OFF
when control pin is
greater than Vih (max)
Reliability and Service Life
Characteristic
Mean time between failure
Symbol
MTBF
Mean time between failure
Mean time between failure
MTBF
MTBF
Min
Typ
Max
551,000
9,009,000
TBA
Units
Hours
Hours
Hours
Notes and Conditions
MIL-HDBK-217F,
Vin = Vin (nom); Iout = Iout
(max); ambient 25ºC;
ground benign environment
Telcordia SR-332
Demonstrated. This entry will be
periodically updated as the
number of test hours increase
3
www.artesyn.com
File Name: lf_sil05e_05.pdf Rev (01): 23 Mar 2004