Audio Processor
11
MX806A
Upon power-up the value of the “bits” in this device will be random (either “0” or “1”). A General Reset
Command (01H) is required. This command is provided to “reset” all devices on the Command “Data line and
has the following effect on the MX806A:
Control Address Command
Mode Address Command
Volume Set
Loaded as 00H
Loaded as 00H
Loaded as 00H
5.1.1 Control Command – (Preceded by A/C 10H)
Settings
MSB
7
0
1
6
0
1
5
0
1
4
0
1
3210
0000
0001
0010
0011
0100
0101
0110
0111
1000
1001
1010
1011
1100
1101
1110
1111
Control Bits
Audio Output (RX)
Disabled
Enabled
Modulation Drives
Disabled
Enabled
Pre-Emphasis
Bypass
Enabled
Input Select
RX In
Mic. In
Input Level Set
Input Amp Disabled
–4.0dB
–3.0dB
–2.0dB
–1.0dB
0dB
1.0dB
2.0dB
3.0dB
4.0dB
5.0dB
6.0dB
7.0dB
8.0dB
9.0dB
10.0dB
Table 4: Control Commands