SP8852D
Bit 15
0
0
1
1
Bit 14
Current Multiplication
Factor
0
1.0
1
1.5
0
2.5
1
4.0
Table 1
] * Pin 19 current
Vcc 1 . 6V
Rset
+ Phase detector gain
p ń Ipin 19(mA)
multiplication factor
2
mA radian
To allow for control direction changes introduced by the
design of the PLL, bit 12 on the input bus address 0 can be
programmed to reverse the sense of the phase detector by
transposing the Fpd and Fref connections. In order that any
external phase detector will also be reversed by this
programming bit, the Fpd/Fref outputs are also interchanged by
bit 12 as shown in Table 2.
Output for RF Phase Lag
Sense Bit (Bit 12)
Pin 20
1
Current Source
0
Current Sink
Table 2
The Fpd and Fref signals to the phase detector are
available on pin 24 and 25 and may be used to monitor the
frequency input to the phase detector or used in conjunction
with an external phase detector. These outputs may be
programmed by bits 10 and 11 of word 0 according to table
3. State 3 where the outputs are disabled by the lock detect
circuit is useful where the user wishes to use an external
phase detector. The internal phase/frequency detector may
be used to pull the loop into lock and an automatic switch
over to the external phase detector made. When the Fpd/Fref
W outputs are to be used at high frequencies, an external pull
down resistor of minimum value 330 may be connected to
ground to reduce the fall time of the output pulse.
Bit 11
0
0
1
1
Bit 10
0
1
0
1
Phase Detector State
Phase detector enable
Fpd/Fref outputs off
Phase detector enable
Fpd/Fref outputs on
Phase detector disable by lock detect
Fpd/Fref outputs on
Phase detector disabled
Fpd/Fref outputs on
Table 3
The charge pump connections to the loop amplifier consist
of the charge pump output and the charge pump reference.
The matching of the charge pump up and down currents will
only be maintained if the charge pump output is held at a
voltage equal to the charge pump reference using an
operational amplifier to produce a virtual earth condition at pin
20.
The lock detect circuit can drive an LED to give visual
indication of phase lock or provide an indication to the control
system if a pull up resistor is used in place of the LED. A small
capacitor connected from the C–lock detector pin to ground
may be used to delay lock detect indication and remove
glitches produced by momentary phase coincidence during
lock up.
PIN 40
BIT 15
0
PIN 11
BIT 0
29 28 27 26 25 24 23 22 21 20
ADDRESS NOT USED
PHASE
DETECTOR
STATE
CONTROL
see Table 3
TEN BIT REFERENCE COUNTER
PHASE
DETECTOR
SENSE
CONTROL
see Table 2
PIN 40
BIT 15
REFERENCE WORD BIT ALLOCATION
PIN 11
BIT 0
1
213 212 211 210 29 28 27 26 25 24 23 22 21 20
ADDRESS
PHASE
DETECTOR
GAIN
CONTROL
see Table 1
M COUNTER
RF DIVISION RATIO BIT ALLOCATION
3 BIT A
COUNTER
Fig. 6 Programming data format