DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

SPU04N60S5 データシートの表示(PDF) - Infineon Technologies

部品番号
コンポーネント説明
メーカー
SPU04N60S5
Infineon
Infineon Technologies Infineon
SPU04N60S5 Datasheet PDF : 12 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
SPU04N60S5
SPD04N60S5
Electrical Characteristics , at Tj = 25 °C, unless otherwise specified
Parameter
Symbol
Conditions
Values
Unit
min. typ. max.
Characteristics
Transconductance
gfs
VDS2*ID*RDS(on)max,
-
2.5
-S
ID=2.8A
Input capacitance
Ciss
VGS=0V, VDS=25V,
- 580 - pF
Output capacitance
Coss
f=1MHz
- 220 -
Reverse transfer capacitance Crss
-
7
-
Effective output capacitance,3) Co(er) VGS=0V,
-
20
- pF
energy related
VDS=0V to 480V
Effective output capacitance,4) Co(tr)
-
35
-
time related
Turn-on delay time
Rise time
t d(on)
VDD=350V, VGS=0/10V,
-
55
- ns
ID=4.5A, RG=18
tr
VDD=350V, VGS=0/10V,
-
30
-
Turn-off delay time
Fall time
ID=4.5A, RG=18
t d(off)
VDD=350V, VGS=0/10V,
-
tf
ID=4.5A, RG=18
-
60 90
15 22.5
Gate Charge Characteristics
Gate to source charge
Gate to drain charge
Qgs
Qgd
VDD=350V, ID=4.5A
Gate charge total
Qg
VDD=350V, ID=4.5A,
VGS=0 to 10V
Gate plateau voltage
V(plateau) VDD=350V, ID=4.5A
-
4.5
- nC
-
11
-
- 17.6 22.9
-
8
-V
1Repetitve avalanche causes additional power losses that can be calculated as PAV=EAR*f.
2Device on 40mm*40mm*1.5mm epoxy PCB FR4 with 6cm² (one layer, 70 µm thick) copper area for drain
connection. PCB is vertical without blown air.
3Co(er) is a fixed capacitance that gives the same stored energy as Coss while VDS is rising from 0 to 80% VDSS.
4Co(tr) is a fixed capacitance that gives the same charging time as Coss while VDS is rising from 0 to 80% VDSS.
Rev. 2.5
Page 3
2008-04-08

Share Link: 