1 2 3 4 5 6 7 8
ELECTRICAL SPECIFICATIONS
TA=TMIN to TMAX, VDD=+5.0 V, ƒS=60 MSPS, VREFH=3.0 V, VREFL=2.0 V, OVDD=3.0 V, unless otherwise specified.
PARAMETERS
TEST
CONDITIONS
TEST
LEVEL
SPT7866
MIN
TYP
Power Supply Requirements
VDD Voltage (Analog Supply)
OVDD Voltage (Output Supply)
VDD Current
OVDD Current
Power Dissipation
External Voltage Reference
Internal Voltage Reference
Sleep Mode Power Dissipation
External Voltage Reference
Internal Voltage Reference
Power Supply Rejection Ratio (PSRR)
IV
4.75
5.0
IV
2.7
3.0/5.0
VI
98
VI
10
VI
482
VI
480
VI
45
VI
55
V
51
Internal References
Common Mode Voltage Reference (VCM) IO = –1 µA
Common Mode Voltage Tempco
Output Impedance (VCM)
Reference Low Output Voltage (VREFL) (EXT/INT) = 0
Reference High Output Voltage (VREFH) (EXT/INT) = 0
External References
Reference Low Input Voltage Range
Reference High Input Voltage Range
(EXT/INT) = 1
(EXT/INT) = 1
VI
2.4
2.5
V
100
V
1.4
VI
1.95
2.0
VI
2.95
3.0
IV
1.7
2.0
IV
2.7
3.0
Digital Outputs
Output Voltage High
Output Voltage Low
Digital Inputs
Input High Voltage
Input Low Voltage
Input High Current
Input Low Current
IO = –2 mA
IO = 2 mA
VI
85% OVDD 90% OVDD
VI
0.2
VI
80% VDD
VI
VI
VI
Clock Inputs
Clock Inputs High Voltage
Clock Inputs Low Voltage
Clock Inputs High Current
Clock Inputs Low Current
VI
2
VI
VI
VI
MAX UNITS
5.25 V
5.25 V
mA
mA
513 mW
512 mW
47
mW
57
mW
dB
2.6
V
ppm/°C
k
2.05 V
3.05 V
2.3
V
3.3
V
OVDD V
0.4
V
V
20% VDD V
±100 µA
±100 µA
5
V
0.4
V
±115 µA
±115 µA
TEST LEVEL CODES
TEST LEVEL
All electrical characteristics are subject to the
I
following conditions:
II
All parameters having min/max specifications are
guaranteed. The Test Level column indicates the
III
specific device testing actually performed during
production and Quality Assurance inspection. Any
IV
blank section in the data column indicates that the
specification is not tested at the specified
V
condition.
VI
TEST PROCEDURE
100% production tested at the specified temperature.
100% production tested at TA = +25 °C, and sample tested
at the specified temperatures.
QA sample tested only at the specified temperatures.
Parameter is guaranteed (but not tested) by design and
characterization data.
Parameter is a typical value for information purposes only.
100% production tested at TA = +25 °C. Parameter is
guaranteed over specified temperature range.
SPT7866
3
11/20/01

Share Link: 