DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

TEN6 データシートの表示(PDF) - Traco Power

部品番号
コンポーネント説明
メーカー
TEN6
Traco
Traco Power Traco
TEN6 Datasheet PDF : 3 Pages
1 2 3
DC/DC Converters
TEN 6 Series
6 Watt
Input Specifications
Input current no load /full load
24 Vin models
48 Vin models
22 mA / 600 mA typ. (at 12 VDC Vin)
20 mA / 300 mA typ. (at 24 VDC Vin)
11 mA / 300 mA typ. (at 24 VDC Vin)
10 mA / 150 mA typ. (at 48 VDC Vin)
Start-up voltage /
under voltage shut down
24 Vin models 8.5 VDC / 8.0 VDC typ.
48 Vin models 17 VDC / 16 VDC typ.
Surge voltage (1 sec. max.)
24 Vin models 50 V max.
48 Vin models 100 V max.
Reverse voltage protection
1.0 A max.
Conducted noise (input)
EN 55022 level A, FCC part 15, level A
Output Specifications
Voltage set accuracy
±1%
Regulation
– Input variation Vin min. to Vin max.
– Load variation 10 – 100 %
– single output models
– dual output models balanced load
– dual output models unbalanced load
± 0.3 % max.
± 1.0 % max.
± 1.0 % max.
± 3.0 % max.
Ripple and noise (20 MHz Bandwidth)
75 mVpk-pk max
Temperature coefficient
± 0.02 % / K
Current limitation
> 110% of Iout max., constant current
Short circuit protection
indefinite (automatic recovery)
Capacitive load
– single output models
– dual output models
3’000 µF max.
680 µF max.
General Specifications
Temperature ranges
– Operating
– Case temperature
– Storage
– 40 °C ... + 85 °C
+ 100 °C max.
– 55 °C ... + 125 °C
Derating
3.5% /K above 70°C
Humidity (non condensing)
95 % rel H max.
Reliability, calculated MTBF (MIL-HDBK-217 E)
>1 Mio. h @ + 25 °C
Isolation voltage
Input/Output
1’500 VDC
Isolation capacity
Input/Output
380 pF typ
Isolation resistance
Input/Output (500 VDC)
> 1‘000 M Ohm
Switching frequency
300 kHz typ. (Pulse frequency modulation PFM)
Safety standards
UL/cUL 60950 , IEC 60950, EN 60950
Compliance up to 60 VDC input voltage
(SELV limit)
Safety approval
CSA (File no. 226037)
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
http://www.tracopower.com
Page 2 of 3

Share Link: 