DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

TH8082K データシートの表示(PDF) - Melexis Microelectronic Systems

部品番号
コンポーネント説明
メーカー
TH8082K
Melexis
Melexis Microelectronic Systems  Melexis
TH8082K Datasheet PDF : 26 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
TH8082
Enhanced SoloLIN Transceiver
2.4 Dynamic Characteristics
Unless otherwise specified all values in the following table are valid for VS = 7 to 18V and
TAMB= -40 to 125oC.
Parameter
Symbol
Condition
Min
Typ
Max Unit
Propagation delay transmitter [1] [3] [6]
ttrans_pd
Bus loads: 1K/1nF,
660/6.8nF, 500/10nF
Propagation delay transmitter symmetry [3] [6] ttrans_sym Calculate ttrans_pdf - ttrans_pdr
-2
5
µs
2
µs
Propagation delay receiver [1] [3] [6] [7] [9]
trec_pdf CRxD = 25pF
6
µs
Propagation delay receiver symmetry [3] [6] [7]
trec_sym Calculate ttrans_pdf - ttrans_pdr
-2
2
µs
Slew rate rising and falling edge, high batttery
[5] [6]
|tSR_HB|
Bus load, VS = 18V
1K/1nF
660/6.8nF
500/10nF
1
2
3 V/µs
Slew rate rising and falling edge, low batttery
[5] [6]
|tSR_LB|
Bus load, VS = 7V
1K/1nF
660/6.8nF
500/10nF
0.5
2
3 V/µs
Slope Symmetry, high battery [5] [6]
Bus load, VS = 18V
1K/1nF
tssym_HB 660/6.8nF
-5
500/10nF
Calculate t - t
sdom srec
+5 µs
Bus duty cycle 1 [7]
D1 Calculate tBUS_rec(min)/100µs
0.396
Bus duty cycle 2 [7]
D2 Calculate tBUS_rec(max)/100µs
0.581
Receiver debounce time [2] [5] [9]
Wake-up filter time
EN - debounce time
trec_deb BUS rising and falling edge
1.5
4
µs
twu
Sleep mode,
BUS rising and falling edge
30
150 µs
ten_deb
Normal to sleep mode
transition
10
20
40 µs
[1] Propagation delays are not relevant for LIN protocol transmission, value only information parameter
[2] No production test, guaranteed by design and qualification
[3] See Figure 2 - Input / Output timing
[4] See Figure 8 - Slope time and slew rate calculation
[5] See Figure 3 – Receiver debouncing a and propagation delay
[6] In accordance to LIN Physical Layer Specification 1.3
[7] In accordance to LIN Physical Layer Specification 2.0
[8] See Figure 9 - Duty cycle calculation in accordance to LIN 2.0
[9] This parameter is tested by applying a wave signal to the bus. The minimum slew rate for the bus rising and falling edge is
50V/µs
TH8082 – Datasheet
3901008082
Page 8 of 26
Feb 2007
Rev 007

Share Link: 