EN 60747-5-5 Option:(D4)
TLP718
Types
: TLP718, TLP718F
Type designations for “option: (D4)”, which are tested under EN 60747 requirements.
Ex.: TLP718 (D4-TP,F)
D4 : EN 60747 option
TP : Standard tape & reel type
F : [[G]]/RoHS COMPATIBLE (Note 1)
Note: Use TOSHIBA standard type number for safety standard application.
Ex.: TLP718 (D4-TP,F) → TLP718
Note 1 : Please contact your TOSHIBA sales representative for details as to environmental matters such as the RoHS
compatibility of Product.
The RoHS is the Directive 2011/65/EU of the European Parliament and of the Council of 8 June 2011 on
the restriction of the use of certain hazardous substances in electrical and electronic equipment.
EN 60747 Isolation Characteristics
Description
Application classification
for rated mains voltage ≤ 300 Vrms
for rated mains voltage ≤ 600 Vrms
Climatic classification
Pollution degree
Maximum operating insulation voltage
Input to output test voltage, method A
Vpr = 1.6×VIORM, type and sample test
tp = 10 s, partial discharge < 5 pC
TLPxxx type
TLPxxxF type
TLPxxx type
TLPxxxF type
Input to output test voltage, method B
Vpr = 1.875×VIORM, 100% production test
tp = 1 s, partial discharge < 5 pC
TLPxxx type
TLPxxxF type
Highest permissible overvoltage
(transient overvoltage, tpr = 60 s)
Safety limiting values (max permissible ratings in case of
fault, also refer to thermal derating curve)
current (input current IF, Psi = 0)
power (output or total power dissipation)
temperature
Insulation resistance,
VIO = 500 V, Ta = 25°C
VIO = 500 V, Ta = 100°C
VIO = 500 V, Ta = Tsi
Symbol
Rating
Unit
VIORM
Vpr
Vpr
VTR
I-IV
—
I-III
40 / 100 / 21 —
2
—
890
Vpk
1140
1424
Vpk
1824
1670
Vpk
2140
8000
Vpk
Isi
300
mA
Psi
700
mW
Tsi
150
°C
≥1012
Rsi
≥1011
Ω
≥109
© 2019
6
Toshiba Electronic Devices & Storage Corporation
2019-06-03