DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

W91-X113-5 データシートの表示(PDF) - Tyco Electronics

部品番号
コンポーネント説明
メーカー
W91-X113-5
MACOM
Tyco Electronics MACOM
W91-X113-5 Datasheet PDF : 6 Pages
1 2 3 4 5 6
Ordering Information
W6 Series
Typical Part No. B W 67- X 2 Q 1 2- 20
1. Circuit Breaker Mounting:
W = #6-32 mounting threads.
M = M3.0 x 0.5 mounting threads.
X = Snap-in mounting. (Not available in rocker actuated models.)
2. Number of Poles:
67 = Single pole
68 = Two pole
69 = Three pole
70 = Four pole
3. Circuit Function: (Only X is VDE approved)
A = Series trip with auxiliary switch (.093” QC)
X = Series trip
4. Actuator: (One actuator per pole)
1 = Black toggle 3 = Black rocker
2 = White toggle 4 = White rocker
5 = Red rocker
6 = Grey rocker
9 = Red toggle
5. Termination:
Q = .250” QC (DIN 46 244) 25A Max. VDE
S = #8-32 screw
Note: “T” termination must be used for all ratings of 31 amps or above.
T = #10-32 screw
6. Maximum Line Voltage: (See Table 1 for current ranges)
UL/CSA 1 = 277VAC, 50/60 Hz.
VDE
TYPES 2 = 277/480
TYPES
3 = 250VAC, 400 Hz.
5 = 65VDC
7 = AC/DC 277VAC or 65VDC
(Delay curve 34 must be specified.)
1 = 250VAC, 415/240VAC
5 = 65VDC
7 = AC/DC 250VAC, 415/240VAC, 65VDC
(Delay curve 34 must be specified.)
7. Time Delay Curve:
0 = Instantaneous
2 = Standard delay
3 = Short delay
53 = DC high inrush
10 = AC high inrush (Motor start)
12 = AC high inrush version of #2
13 = AC high inrush version of #3
34 = Combination AC/DC standard delay
Notes: Curves may be specified with increased pulse tolerance for 1/2 cycle by
adding "P" after curve, See delay curve section for availability and details.
8. Amp Rating:
0.20 0.50 1.0
0.25 0.75 1.5
2.0
3.0
2.5
3.5
4.0
6.0
7.5
9.0
11.0
15.0
25.0 35.0 45.0 Consult factory for
5.0
7.0
8.0
10.0 12.0 20.0 30.0 40.0 50.0 other values.
9. VDE Approval: (See Table 2 for auxiliary switch ratings)
Blank = UL/CSA approved breaker
V = VDE approved breaker without auxiliary switch
V1 = VDE approved breaker with 10 amp VDE auxiliary switch
V2 = VDE approved breaker with 5 amp VDE auxiliary switch
V3 = VDE approved breaker with 0.1 amp VDE auxiliary switch
Stock Items - We recommend that our authorized distributors stock the following items for immediate delivery.
W67-A2Q12-5
W67-A2Q12-10
W67-X2Q10-3
W67-X2Q10-5
W67-X2Q12-2
W67-X2Q12-3
W67-X2Q12-5
W67-X2Q12-7
W67-X2Q12-10
W67-X2Q12-15
W67-X2Q12-20
W67-X2Q12-30
W67-X2Q13-1
W67-X2Q13-2
W67-X2Q13-3
W67-X2Q13-10
W67-X2Q13-15
W67-X2Q13-20
W67-X2Q13-25
W67-X2Q13-30
W67-X2Q50-5
W67-X2Q50-10
W67-X2Q52-5
W67-X2Q52-10
W67-X2Q52-15
W67-X2Q52-20
W67-X2Q52-30
W67-X2Q110-15
W67-X2Q110-20
W68-X2Q12-3
W68-X2Q12-5
W68-X2Q12-7
W68-X2Q12-10
W68-X2Q12-15
W68-X2Q12-20
W68-X2Q12-25
W68-X2Q12-30
W68-X2Q13-15
W68-X2Q110-10
W68-X2Q110-20
W69-X2Q12-5
W69-X2Q12-10
W69-X2Q12-15
W69-X2Q12-20
W69-X2Q12-25
W69-X2Q12-30
W69-X2Q110-20
W69-X2Q110-30
Ordering Information
W9 Series
Typical Part No. B W 91- X 1 1 2- 20
1. Circuit Breaker Mounting:
W = #6-32 mounting threads.
M = M3.0 x 0.5 mounting threads.
2. Number of Poles:
91 = Single pole
92 = Two pole
93 = Three pole
94 = Four pole
3. Circuit Function: (Only X is VDE approved)
A = Series trip with auxiliary switch (.093” QC)
X = Series trip
4. Actuator: (One actuator per pole):
1 = Black toggle
2 = White toggle
5. Maximum Line Voltage: (See Table 1 for current ranges)
UL/CSA 1 = 277VAC, 50/60 Hz.
VDE 1 = 250VAC, 415/240VAC
TYPES 2 = 277/480
TYPES 5 = 65VDC
3 = 250VAC, 400 Hz.
7 = AC/DC 250VAC, 415/240VAC, 65VDC
5 = 65VDC
(Delay curve 34 must be specified.)
7 = AC/DC 277VAC or 65VDC
(Delay curve 34 must be specified.)
6. Time Delay Curve:
0 = Instantaneous
2 = Standard delay
3 = Short delay
53 = DC high inrush
10 = AC high inrush (Motor start)
12 = AC high inrush version of #2
13 = AC high inrush version of #3
34 = Combination AC/DC standard delay
Notes: Curves may be specified with increased pulse tolerance for 1/2 cycle
by adding "P" after curve. See delay curve section for availability and details.
7. Amp Rating:
0.20
0.75
2.0
0.25
1.0
2.5
0.50
1.5
3.0
3.5
6.0
4.0
7.0
5.0
7.5
8.0
11.0
9.0
12.0
10.0
15.0
20.0
25.0
30.0
35.0
40.0
45.0
50.0
Consult factory for other values
8. VDE Approval: (See Table 2 for auxiliary switch ratings)
Blank = UL/CSA approved breaker
V = VDE approved breaker without auxiliary switch
V1 = VDE approved breaker with 10 amp VDE auxiliary switch
V2 = VDE approved breaker with 5 amp VDE auxiliary switch
V3 = VDE approved breaker with 0.1 amp VDE auxiliary switch
Stock Items - We recommend that our authorized distributors stock the following items for immediate delivery.
W91-X112-1
W91-X112-2
W91-X112-3
W91-X112-5
W91-X112-7
W91-X112-10
W91-X112-15
W91-X112-20
W91-X112-40
W91-X112-50
W91-X113-5
W91-X113-10
W91-X113-15
W91-X150-5
W91-X152-10
W91-X152-15
W91-X152-20
W91-X152-30
W91-X152-40
W91-X152-50
W91-X1110-20
W92-X112-1
W92-X112-2
W92-X112-3
W92-X112-5
W92-X112-7
W92-X112-10
W92-X112-15
W92-X112-20
W92-X112-25
W92-X112-30
W92-X112-40
W92-X112-50
W92-X113-15
W92-X113-20
W92-X1110-20
W92-X1110-30
W93-X112-5
W93-X112-10
W93-X112-15
W93-X112-20
W93-X112-25
W93-X112-30
W93-X112-40
W93-X112-50
W93-X1110-20
W93-X1110-30

Share Link: 