MC10ELT25, MC100ELT25
Table 4. 10ELT SERIES NECL INPUT DC CHARACTERISTICS VCC = 5.0 V; VEE = −5.0 V; GND = 0 V (Note 2)
−40°C
25°C
85°C
Symbol
Characteristic
Min Typ Max Min Typ Max Min Typ Max Unit
VIH
Input HIGH Voltage (Single−Ended) (Note 3) −1230
−890 −1130
−810 −1060
−720 mV
VIL
Input LOW Voltage (Single−Ended) (Note 3) −1950
−1500 −1950
−1480 −1950
−1445 mV
VBB
Output Voltage Reference
−1.43
−1.30 −1.35
−1.25 −1.31
−1.19 V
VIHCMR Input HIGH Voltage Common Mode Range
(Differential) (Notes 3 and 4)
−2.8
0.0 −2.8
0.0 −2.8
0.0 V
IIH
Input HIGH Current
IIL
Input LOW Current
255
175
175 mA
0.5
0.5
0.3
mA
NOTE: Device will meet the specifications after thermal equilibrium has been established when mounted in a test socket or printed circuit
board with maintained transverse airflow greater than 500 lfpm. Electrical parameters are guaranteed only over the declared
operating temperature range. Functional operation of the device exceeding these conditions is not implied. Device specification limit
values are applied individually under normal operating conditions and not valid simultaneously.
2. Input parameters vary 1:1 with GND. VEE can vary +0.06 V to −0.5 V.
3. TTL output RL = 500 W to GND
4. VIHCMR min varies 1:1 with VEE, VIHCMR max varies 1:1 with GND.
Table 5. 100ELT SERIES NECL INPUT DC CHARACTERISTICS VCC = 5.0 V; VEE = −5.0 V; GND = 0 V (Note 5)
−40°C
25°C
85°C
Symbol
Characteristic
Min Typ Max Min Typ Max Min Typ Max Unit
VIH
VIL
VBB
VIHCMR
Input HIGH Voltage (Single−Ended) (Note 6)
Input LOW Voltage (Single−Ended) (Note 6)
Output Voltage Reference
Input HIGH Voltage Common Mode Range
(Differential) (Notes 6 and 7)
−1165
−1810
−1.38
−2.8
−880 −1165
−1475 −1810
−1.26 −1.38
0.0 −2.8
−880 −1165
−1475 −1810
−1.26 −1.38
0.0 −2.8
−880 mV
−1475 mV
−1.26 V
0.0 V
IIH
Input HIGH Current
IIL
Input LOW Current
255
175
175 mA
0.5
0.5
0.5
mA
NOTE: Device will meet the specifications after thermal equilibrium has been established when mounted in a test socket or printed circuit
board with maintained transverse airflow greater than 500 lfpm. Electrical parameters are guaranteed only over the declared
operating temperature range. Functional operation of the device exceeding these conditions is not implied. Device specification limit
values are applied individually under normal operating conditions and not valid simultaneously.
5. Input parameters vary 1:1 with GND. VEE can vary +0.8 V to −0.5 V.
6. TTL output RL = 500 W to GND
7. VIHCMR min varies 1:1 with VEE, VIHCMR max varies 1:1 with GND.
Table 6. TTL OUTPUT DC CHARACTERISTICS VCC = 4.5 V to 5.5 V; TA = −40°C to +85°C
Symbol
Characteristic
Condition
Min
Typ
Max
Unit
VOH
VOL
ICCH
ICCL
IEE
IOS
Output HIGH Voltage
Output LOW Voltage
Power Supply Current
Power Supply Current
Negative Power Supply Current
Output Short Circuit Current
IOH = −3.0 mA
IOL = 24 mA
2.4
11
13
15
−150
V
0.5
V
16
mA
18
mA
21
mA
−60
mA
NOTE: Device will meet the specifications after thermal equilibrium has been established when mounted in a test socket or printed circuit
board with maintained transverse airflow greater than 500 lfpm. Electrical parameters are guaranteed only over the declared
operating temperature range. Functional operation of the device exceeding these conditions is not implied. Device specification limit
values are applied individually under normal operating conditions and not valid simultaneously.
http://onsemi.com
3